113
113
EN
ESIM384 Installation and Configuration Manual v1.1
Enable keypad
partition switch
EKB2
Menu path:
OK
→
iiii
→
OK
→
PRIMARY SettINGS
→
OK
→
KeYPAD PARtItION
→
OK
→
PARtItION SWItCH
→
OK
→
eNABLe
→
OK
Value:
iiii
– 4-digit installer code.
EKB3/
EKB3W/
EWKB4
Enter parameter 77 and parameter status value:
77 1#
Example:
771#
ElDES
Config-
uration
software
this operation may be carried out from the PC using the
ELDES Configuration
software.
Disable keypad
partition switch
EKB2
Menu path:
OK
→
iiii
→
OK
→
PRIMARY SettINGS
→
OK
→
KeYPAD PARtItION
→
OK
→
PARtItION SWItCH
→
OK
→
DISABLe
→
OK
Value:
iiii
– 4-digit installer code.
EKB3/
EKB3W/
EWKB4
Enter parameter 77 and parameter status value:
77 0 #
Example:
770#
ElDES
Config-
uration
software
this operation may be carried out from the PC using the
ELDES Configuration
software.
notE:
Keypad partition switch can only be used when the system is partitioned.
23.4. User/Master Code Partition
User/master code partition determines which system partition (-s) can be armed/disarm using a certain user/master code. User/master
code must be assigned to the same partition as the keypad (see
23.3. Keypad Partition and Keypad Partition Switch
) in order to arm/
disarm the system by eKB2/eKB3/eKB3W/eWKB4 keypad . For more details on system arming/disarming by the keypad, please refer to
12.3. EKB2 Keypad and User/Master Code
,
12.4. EKB3 Keypad and User/Master Code
and
12.5. EKB3W/EWKB4 Keypad and
User/Master Code
.
Set user/master
code partition
EKB2
Menu path:
Master code:
OK
→
mmmm
→
OK
→
CODeS
→
OK
→
MASteR CODe
→
OK
→
PARtItION
→
OK
→
pv
→
OK
User code 2... 17:
...
→
CODeS
→
OK
→
USeR CODe (2-17)
→
OK
→
USeR CODe 2... 17
→
OK
→
PARtItION
→
OK
→
pv
→
OK
User code
18... 30: ...
→
CODeS
→
OK
→
USeR CODe (18-30)
→
OK
→
USeR CODe 18... 30
→
OK
→
PARtItION
→
OK
→
pv
→
OK
Value:
mmmm
– 4-digit master code;
pv
– partition value, range – [01... 15].
EKB3/
EKB3W/
EWKB4
Press , 5, enter 01/user code slot, partition value and master code:
Master code:
5 01 pv mmmm #
User code:
5 us pv mmmm #
Value:
us
- user code slot, range - [02... 30];
pv
– partition value, range – [01... 15];
mmmm
-
4-digit master code.
Example:
504081111#
ElDES
Config-
uration
software
this operation may be carried out from the PC using the
ELDES Configuration
software.
notE for EKB3/EKB3W/EWKB4:
the Configuration mode must be deactivated, while managing user and master code partition.