73
73
EN
ESIM384 Installation and Configuration Manual v1.1
18. ProGraMMaBlE (PGM) oUtPUtS
A PGM output is a programmable output that toggles to its set up state when a specific event has occurred in the system, the scheduled
weekday and time has come or if the user has initiated the PGM output state change manually. Normally, PGM outputs can be used to open/
close garage doors, activate lights, heating, watering and much more. When a PGM output turns ON, the system triggers any device or relay
connected to it.
eSIM384 comes equipped with four open-collector PGM outputs allowing to connect up to four devices or relays. For more details on PGM
output expanding, please refer to
18.2. PGM output Expansion
.
ESIM384 PGM outputs are classified by 4 categories:
PGM output category
Description
Max. number of PGM
outputs per device
Max. number of PGM
outputs in total
On-board PGM Outputs
Built-in wired PGM outputs of eSIM384 alarm system.
4
4
ePGM8 PGM Outputs
PGM outputs of ePGM8 - hardwired PGM output expan-
sion module.
8
8
ePGM1 PGM Outputs
PGM outputs of ePGM1 - hardwired zone and PGM output
expansion module.
2
4
Wireless PGM Outputs
Non-physical PGM outputs automatically created by con-
nected wireless devices.
2*
48**
* - Depends on the connected wireless device.
** - Available only if no ePGM1 PGM outputs are present.
For PGM output wiring diagram, please refer to
2.3.6. relay finder® (for example, model 40.61.9.12) with terminal Socket (for
example, model 95.85.3)
.
18.1. PGM output numbering
the PGM output numbers ranging from C1 through C16 are permanently reserved for on-board PGM outputs even if ePGM8 module mode is
disabled. the C17-C48 PGM output number are automatically assigned in the chronological order to the devices connected to the system:
ePGM1 modules and wireless devices.
18.2. PGM output Expansion
For additional electrical appliance connection, the number of PGM outputs can be expanded by:
•
connecting ePGM8 hardwired PGM output expansion module. (for more details on technical specifications and installation, please refer
to the latest user manual of the device located at www.eldesalarms.com).
•
connecting ePGM1 hardwired zone and PGM output expansion module (for more details on technical specifications and installation,
please refer to the latest user manual of the device located at www.eldesalarms.com).
•
pairing the wireless devices (see
19. WIrElESS DEVICES
).
the maximum supported PGM output number is 48.
18.2.1. EPGM8 Mode
ePGM8 is an expansion module, which expands the system with 8 additional hardwired PGM outputs. For more details on technical specifi-
cations and installation, please refer to the latest user manual of the device located at www.eldesalarms.com
Once the ePGM8 module is installed, the ePGM8 mode must be enabled.
Enable EPGM8 mode
EKB2
Menu path:
OK
→
iiii
→
OK
→
USING ePGM8
→
OK
→
eNABLe
→
OK
Value:
iiii
– 4-digit installer code.
EKB3/
EKB3W/
EWKB4
Enter parameter 33 and parameter status value:
33 1 #
Example:
331#
ElDES
Config-
uration
software
this operation may be carried out from the PC using the
ELDES Configuration
software.