ESIM384 Installation and Configuration Manual v1.1
•
Interior follower
– the zone can be violated during exit and entry delay without causing an alarm. If the zone is violated before the
entry delay has begun, it will cause an instant alarm followed by single notification delivery even if the zone has been violated multiple
times while alarm period (by default - 1 minute) is in progress. If another Interior Follower-type zone has been violated it should act in
the same way - cause an instant alarm followed by single notification delivery even if the zone has been violated multiple times while
alarm period (by default - 1 minute) is in progress.
•
Instant
– the alarm is instantly caused if this zone is violated when the system is armed or during entry delay. this zone type is usually
used for doors, windows, shock sensors or other zones.
•
24-Hour
– When the system is either armed or disarmed, the zone will cause instant alarm if violated. Normally, this type of zone is
used for securing the areas that require constant supervisory.
•
Delay
– this zone type can be violated during exit and entry delay without causing an alarm. If the zone is violated when the system
is armed, it will initiate entry delay countdown intended for the user to disarm the system. If the zone remains violated after the exit
delay expires, it will cause an instant alarm. typically, this zone type is used for door contacts installed at designated exit/entry doors.
•
fire
– If this zone type is violated when the system is either armed or disarmed, the alarm will be instantly caused and the siren/bell
will emit pulsating sound. Once the alarm is caused by violating a Fire-type zone followed by turning OFF the alarm using any available
disarm method, the system will ignore the violations of any Fire-type zone (including the repeated violations of the said zone) caused
within a 1-minute time frame. typically, this zone type is used for flame and smoke detectors.
•
Panic/Silent
– this zone operates the same as 24-Hour zone type, but the system will not activate the siren/bell and keypad buzzer if
violated. Normally, this zone type used for panic alarm buttons.
•
Co Sensor
– this zone type operates identically to Fire zone type and it is used for CO (carbon monoxide) detector.
•
report/Control
– this zone operates the same as Panic/Silent zone type, but unique event data message will be transmitted to the
monitoring station if violated. However, no alarm will be caused - the system will NOt dial the listed user phone number regardless of
the status of Call in Case of Alarm feature (enabled or disabled), nor the siren will sound. typically, this zone type is used to report a
certain non-alarm event, such as heating activation or fault.
•
Instant Silent
– this zone operates in the same way as Panic/Silent, but only when the system is armed.
Set zone type for
individual zone
EKB2
Menu path:
On-board zone:
OK
→
iiii
→
OK
→
ZONeS
→
OK
→
ONBOARD ZONeS
→
OK
→
ZONe 1... 16
→
OK
→
tYPe
→
OK
→
INteRIOR FOLLOWeR | INStANt | 24- HOUR | DeLAY | FIRe | PANIC/SILeNt |
CO SeNSOR | RePORt/CtRL | INStANt SILeNt
→
OK
Wireless zone:
OK
→
iiii
→
OK
→
WIReLeSS ZONeS
→
OK
→
WIReLeSS ZONeS 1... 4
→
OK
→
WIReLeSS ZONe 13... 80
→
OK
→
tYPe
→
OK
→
INteRIOR FOLLOWeR | INStANt | 24-HOUR |
DeLAY | FIRe | PANIC/SILeNt | CO SeNSOR | RePORt/CtRL | INStANt SILeNt
→
OK
Keypad zone:
OK
→
iiii
→
OK
→
ZONeS
→
OK
→
KeYPAD ZONeS
→
OK
→
1St... 4tH KeYPAD
ZONe
→
OK
→
tYPe
→
OK
→
INteRIOR FOLLOWeR | INStANt | 24-HOUR | DeLAY | FIRe |
PANIC/SILeNt | CO SeNSOR | RePORt/CtRL | INStANt SILeNt
→
OK
ePGM1 zone:
...
→
1...8. ePGM1 ZONeS 1-16... ePGM1 ZONeS 17-32
→
OK
→
ePGM1 ZONe 1...
32
→
OK
→
INteRIOR FOLLOWeR | INStANt | 24-HOUR | DeLAY | FIRe | PANIC/SILeNt | CO
SeNSOR | RePORt/CtRL | INStANt SILeNt
→
OK
Value:
iiii
– 4-digit installer code.
EKB3/
EKB3W/
EWKB4
Enter parameter 53, zone number and zone type number:
53 nn 1 #
– Interior Follower
53 nn 2 #
– Instant
53 nn 3 #
– 24-Hour
53 nn 4 #
– Delay
53 nn 5 #
– Fire
53 nn 6 #
– Panic/Silent
53 nn 7 #
– CO Sensor
53 nn 8 #
– Report/Control
53 nn 9 #
– Instant Silent
Value:
nn
– zone number, range – [01... 80]
Example:
53125#
ElDES
Config-
uration
software
this operation may be carried out from the PC using the
ELDES Configuration
software.
notE:
the system will NOt activate siren and keypad buzzer only when Panic/Silent, Report/Control or Instant Silent zone type is violated.
14.6. Zone attributes
•
Stay
– If this attribute is enabled, the zone, regardless of its type, will not cause an alarm if violated when the system is StAY-armed.
By enabling this attribute, Alarm Count to Bypass feature will not operate with the same zone. For more details on arming the system
in the Stay mode, please refer to
15. StaY MoDE
.
•
force
– this attribute determines whether the system can be armed or not while a zone is violated resulting in partial arm event. If a