63
63
EN
ESIM384 Installation and Configuration Manual v1.1
14.7. Bypassing and activating Zones
notE for EKB3/EKB3W/EWKB4:
the Configuration mode must remain deactivated before bypassing a violated zone or activating a by-
passed zone.
Zone bypassing allows the user to deactivate a violated zone and arm the system without restoring the zone. If a bypassed zone is violated
or restored during exit/entry delay, or when then system is armed, it will be ignored. When a zone is bypassed, eKB3/eKB3W/eWKB4 key-
pad indicator will light ON and eKB2 keypad will display
icon in the home screen view.
Bypass individual
violated zone
EKB2
Menu path:
OK
→
uumm
→
OK
→
BYPASS
→
OK
→
BYPASS LISt 1... 9
→
OK
→
Z1-zone-name... Z80-zone-
name
→
OK
→
BYPASS
→
OK
Value:
uumm
– 4-digit user/master code;
zone-name
– up to 24 characters zone name.
EKB3/
EKB3W/
EWKB4
Press the
key, enter zone number and user/master code:
nn uumm #
Value:
nn
– zone number, range – [01... 80];
uumm
– 4-digit user/master code.
Example:
091111#
Bypass all violated
zones
EKB2
Menu path:
OK
→
uumm
→
OK
→
BYPASS
→
OK
→
BYP VIOLAteD ZONeS
→
OK
Value:
uumm
– 4-digit user/master code.
the zone will remain bypassed until the system is disarmed. Once the system is disarmed, the corresponding zone state will be indicated
on the keypads (see
32.1.1. EKB2 – lCD Keypad,
32.1.2. EKB3 – lED Keypad
and
19.5. EKB3W/EWKB4 – Wireless lED Keypad
)
and Info SMS text message (see
26. SYStEM InforMatIon. Info SMS
). Alternatively, the user can activate the bypassed zone by the
following configuration methods.
activate bypassed
zone
EKB2
Menu path:
OK
→
uumm
→
OK
→
BYPASS
→
OK
→
BYPASS LISt 1... 9
→
OK
→
Z1-zone-name... Z80-zone-
name
→
OK
→
UNBYPASS
→
OK
Value:
uumm
– 4-digit user/master code;
zone-name
– up to 24 characters zone name.
EKB3/
EKB3W/
EWKB4
Press the key, enter zone number and user/master code:
nn uumm #
Value:
nn
– zone number, range – [01... 80];
uumm
– 4-digit user/master code.
Example:
251111#
notE:
Zones can only be bypassed and activated when the system is not armed.
14.8. Zone names
each zone has a name that can be customized by the user. typically, the name specifies a device type connected to a determined zone
terminal, for
Example:
Kitchen doors opened. the zone names are used in SMS text messages that are sent to the user during alarm, the
By default, the zone names are:
Z1 – Zone1, Z2 – Zone2, Z3 – Zone3, Z4 – Zone4 etc.
Set zone name
SMS
SMS text message content:
ssss_Znn:zone-name
Value:
ssss
– 4-digit SMS password;
nn
– zone number, range – [1... 80];
zone-name
– up to
24 characters zone name.
Example:
1111_Z3:Door sensor triggered
ElDES
Config-
uration
software
this operation may be carried out from the PC using the
ELDES Configuration
software.