181
181
EN
ESIM384 Installation and Configuration Manual v1.1
CoMManD
DEfInItIon
CoDE
CoMManD
ValUE
EXaMPlE
onlY for EKB3!
- Arm all 4 par-
titions simultaneously/ Disarm
and turn OFF the alarm in all 4
partitions simultaneously
0 uumm
uumm – 4-digit user/
master code.
0 2222
Set Alarm duration
10 tt #
tt – alarm duration, range –
[00... 10] minutes.
1007#
Disable Periodic Info SMS
110000#
110000#
Set Periodic Info SMS
frequency and time
11it fff #
it – time, range – [01... 23];
fff – frequency, range –
[00... 125] days
110412#
Disable/ enable system con-
trol from any phone number
120 #/ 121 #
120 #/ 121 #
Set SMS password
14 ssss #
ssss – 4-digit new SMS
password; range –
[0001... 9999].
141111#
Set installer code
16 iiii #
iiii – 4-digit new installer
code; range – [0000... 9999]
162538#
Add user phone number
17 up ttteeellnnuumm #
up – user phone number slot,
range – [01... 10]; ttteeelln-
nuumm – up to 15 digits user
phone number.
17010044170911XXXX1#
enable/Disable Allow adding
new iButton keys mode
18 0 #/ 18 1 #
18 0 #/ 18 1 #
Clear tamper fault
22 #
22#
Disable/ enable MS mode
230# / 231#
230# / 231#
Disable/enable Burglary
alarm/restore data message
24010 #/ 24011 #
24010 #/ 24011 #
Disable/enable Mains
power loss/restore
data message
24020 #/ 24021 #
Disable/enable Armed/
disarmed by user
data message
24030 #/ 24031 #
Disable/enable test
event data message
24040 #/ 24041 #
Disable/enable Battery
failed data message
24050 #/ 24051 #
Disable/enable Battery dead
or missing/battery connec-
tion restore data message
24060 #/ 24061 #
Disable/enable tamper
alarm/restore data message
24070 #/ 24071 #
Disable/enable Instant
Silent zone alarm/re-
store data message
24080 #/ 24081 #
Disable/enable Kronos
ping data message
24090 #/ 24091 #
Disable/enable System
started data message
24100 #/ 24101 #