ESIM384 Installation and Configuration Manual v1.1
Set zone connection
type of “non atZ”
mode for on-board and
EPGM1 zones
ElDES
Config-
uration
soft-
ware
this operation may be carried out from the PC using the
ELDES Configuration
software.
notE:
type 3 is NOt supported by keypad zones.
14.4. atZ (advanced technology Zone) Mode
the AtZ mode is a software-based feature that doubles the number of on-board zones and enables two detection devices to be installed
per 1 zone terminal. Once this mode is enabled, the zone connection type 4 is set automatically. the detection devices must be wired to the
on-board zone terminals as indicated in the wiring diagram of the associated zone connection type. Different zone connection types of AtZ
mode can be individually assigned to each on-board zone pair i.e. Z1 - Z9, Z2 - Z10 etc. .
Once enabled, the AtZ mode DOeS NOt affect ePGM1 zones, nor keypad zones and applies to on-board zones only. the AtZ mode is NOt sup-
ported by ePGM1 and keypad zones.
Zone connection types featured by atZ mode are the following:
•
type 4
– Parallel wiring of 2 NC (normally-closed) detection devices with 5,6kΩ and 3,3kΩ eOL (end-of-line) resistors respectively.
5,6kΩ eOL resistor corresponds to zones ranging from Z1 through Z8, while 3,3kΩ eOL resistor corresponds to zones ranging from Z9
through Z16.
•
type 5
– Combination of consecutive and parallel wiring of tamper with 5,6kΩ eOL resistor and 2 NC (normally-closed) detection devic-
es with 5,6kΩ and 3,3kΩ eOL resistors respectively. 5,6kΩ eOL resistor corresponds to zones ranging from Z1 through Z8, while 3,3kΩ
eOL resistor corresponds to zones ranging from Z9 through Z16.
For zone wiring diagrams of the AtZ mode, please refer to
2.3.2. Zone Connection types
.
Enable atZ mode
EKB2
Menu path:
OK
→
iiii
→
OK
→
ZONeS
→
OK
→
AtZ MODe
→
OK
→
eNABLe
→
OK
Value:
iiii
– 4-digit installer code.
EKB3/
EKB3W/
EWKB4
Enter parameter 28 and parameter status value:
28 1 #
Example:
281#
ElDES
Config-
uration
software
this operation may be carried out from the PC using the
ELDES Configuration
software.
Disable atZ mode
EKB2
Menu path:
OK
→
iiii
→
OK
→
ZONeS
→
OK
→
AtZ MODe
→
OK
→
DISABLe
→
OK
Value:
iiii
– 4-digit installer code.
EKB3/
EKB3W/
EWKB4
Enter parameter 28 and parameter status value:
28 0 #
Example:
280#
ElDES
Config-
uration
soft-
ware
this operation may be carried out from the PC using the
ELDES Configuration
software.
Set zone connection
type of atZ mode for
on-board zones
ElDES
Config-
uration
soft-
ware
this operation may be carried out from the PC using the
ELDES Configuration
software.