50
50
EN
ESIM384 Installation and Configuration Manual v1.1
•
Partitioned system - arming a single partition
– to arm a different partition than the keypad is assigned to, use keypad partition
switch feature (by default – disabled; see
23.3. Keypad Partition and Keypad Partition Switch
) before the arming process.
Switch keypad par-
tition
Hold the [1]... [2] key and release it after 3 short beeps:
Value:
[1]... [2] key – partition number 1... 2 respectively.
Once the partition is switched, indicator will light ON in eKB3W/eWKB4 keypad’s section A (= Partition 1) or B (= Partition 2) and a by
entering a valid user/master code, the system will initiate exit delay, the keypad’s buzzer will emit short beeps and the indicator will
light ON in the respective eKB3W/eWKB4 keypad’s section. When the system is successfully armed, the keypad’s buzzer will silent down.
arm the system
Enter user/master code:
uumm
Value:
uumm
– 4-digit user/master code.
Example:
2222
to arm multiple partitions, please arm the partitions one by one by following the aforementioned procedure.
notE:
If the user fails to enter a correct user/master code 10 times in a row, the system will block the keypad for 2 minutes. While the
keypad is blocked, the system prevents from entering any user/master code. the keypad will automatically unblock once the 2-minute
time has expired/
12.5.2. Cancelling System arming
to cancel the arming process, enter the user/master code again during exit delay countdown.
12.5.3. Disarming the System and turning off the alarm
to disarm and turn OFF the alarm, enter any out of 29 available 4-digit user codes or master code using the number keys on the keypad. By
default, the system disarming process is as follows:
•
non-partitioned system
– When a valid user/ master code is entered, indicator will light OFF.
Disarm the system and
turn off the alarm
Enter user/master code:
uumm
Value:
uumm
– 4-digit user/master code.
Example:
2222
•
Partitioned system - disarming a single partition
– to disarm and turn OFF the alarm in a different partition than the keypad is
assigned to, use keypad partition switch feature (by default – disabled; see
23.3. Keypad Partition and Keypad Partition Switch
)
before the disarming process.
Switch keypad par-
tition
Hold the [1]... [2] key and release it after 3 short beeps:
Value:
[1]... [2] key – partition number 1... 2 respectively.
Once the partition is switched, indicator will light ON in eKB3W/eWKB4 keypad’s section A (= Partition 1) or B (= Partition 2) and a by
entering a valid user/master code, indicator will light OFF.
Disarm the system and
turn off the alarm
Enter user/master code:
uumm
Value:
uumm
– 4-digit user/master code.
Example:
2222
to disarm and turn OFF the alarm in multiple partitions, please disarm the partitions one by one by following the aforementioned procedure.
notE:
If the user fails to enter a correct user/master code 10 times in a row, the system will block the keypad for 2 minutes. While the
keypad is blocked, the system prevents from entering any user/master code. the keypad will automatically unblock once the 2-minute
time has expired.