ESIM384 Installation and Configuration Manual v1.1
ElDES
Config-
uration
software
this operation may be carried out from the PC using the
ELDES Configuration
software.
attEntIon:
the system will NOt send any data to the monitoring station while remote connection, remote firmware update or remote
listening/2-way voice communication is in progress. However, during the remote connection session or remote listening/2-way voice com-
munication process, the data messages will be queued up and transmitted to the monitoring station after the remote connection session or
remote listening/2-way voice communication process is over, while during the remote firmware update process NO data will be queued up
and all data messages will be lost.
attEntIon:
Phone calls via GSM network to the listed user phone number in case of alarm are disabled by force when MS mode is enabled.
notE:
Additional charges may apply for voice calls/data traffic based on your cell phone service plan when using the MS mode.
30.1. Data Messages – Events
the configuration of data messages is based on Ademco Contact ID protocol. the data messages can either be transmitted to the monitor-
ing station alone or with duplication by SMS text message to listed user phone number. For more details on system notifications by SMS text
message, please refer to
27. SYStEM notIfICatIonS
.
Seq. no. Event
Code
Event
Description
1
1110
Fire alarm
transmitted in case a zone of Fire type is violated.
2
3110
Fire restore
transmitted in case a zone of Fire type is restored.
3
1120
Silent/Panic zone alarm
transmitted in case a zone of Silent/Panic type is violated.
4
3120
Silent/Panic zone restore
transmitted in case a zone of Silent/Panic type is restored.
5
1121
Disarmed by user (Duress
code)
transmitted in case the system is disarmed by Duress code.
6
3121
Armed by user (Duress code)
transmitted in case the system is armed by Duress code.
7
1130
Burglary alarm
transmitted in case a zone of Delay (if not disarmed before entry delay countdown
is completed), Interior Follower or Instant type is violated.
8
3130
Burglary restore
transmitted in case a zone of Delay (if not disarmed before entry delay countdown
is completed), Interior Follower or Instant type is restored.
9
1133
24-Hour zone alarm
transmitted in case of zone of 24-Hour type is violated.
10
3133
24-Hour zone restore
transmitted in case of zone of 24-Hour type is restored.
11
1144
tamper alarm
transmitted in case the tamper is violated.
12
3144
tamper restore
transmitted in case the tamper is restored.
13
1146
Instant Silent zone alarm
transmitted in case of zone of Instant Silent type is violated.
14
3146
Instant Silent zone restore
transmitted in case of zone of Instant Silent type is restored.
15
1150
Report/Control zone trigger
transmitted in case of zone of Report/Control type is triggered.
16
3150
Report/Control zone restore
transmitted in case of zone of Report/Control type is restored.
17
1158
temperature risen
transmitted in case of the temperature has increased above the MAX set value.
18
1159
temperature fallen
transmitted in case of temperature has decreased below the MIN set value.
19
1162
CO level critical
transmitted in case the critical level 4 of carbon monoxide (CO) concentration de-
tected by eWF1CO is reached.
20
1301
Mains power loss
transmitted in case the mains power is lost.
21
3301
Mains power restore
transmitted in case the mains power is restored.
22
1302
Low battery
transmitted in case the backup battery voltage is 10.5V or lower / the wireless de-
vice battery level runs below 5%.
23
1308
System shutdown
When the system is running on backup battery power, it transmits the data mes-
sage before the backup battery power is fully depleted.
24
1309
Battery failed
transmitted in case the backup battery resistance is 2Ω or higher.
25
1311
Battery dead or missing
transmitted in case the backup battery is not present or the battery voltage runs
below 5V.
26
3311
Battery connection restore
transmitted in case the backup battery connection is fixed.
27
1321
Siren fail
transmitted in case the siren is disconnected/broken.
28
3321
Siren restore
transmitted in case the siren is connected/fixed.
29
1330
Communication bus fail
transmitted in case the RS485 device, such as keypad, eLAN3-ALARM or ePGM1 is
disconnected/broken.
30
3330
Communication bus restore
transmitted in case the RS485 device, such as keypad, eLAN3-ALARM or ePGM1
is connected/fixed