134
134 EN
ESIM384 Installation and Configuration Manual v1.1
28. EVEnt anD alarM loG
28.1. Event log
the event log allows to chronologically register up to 1024 timestamped records regarding the following system events:
•
System start.
•
System arming/disarming.
•
Zone violated/restored.
•
tamper violated/restored.
•
Zone bypassing.
•
Wireless device management.
•
temperature deviation by MIN and MAX boundaries.
•
System faults.
•
Configuration via USB.
•
User phone number that initiated the remote configuration.
•
Communication with monitoring station status.
the event log is of FIFO (first in, first out) type that allows the system to automatically replace the oldest records with the latest ones.
View event log
EKB2
Menu path:
OK
→
mmmm
→
OK
→
VIeW eVeNt LOG
→
OK
Value:
mmmm
- 4-digit master code.
to export the event log to .log file or clear it, please refer to the following configuration method.
Export/clear event log
ElDES
Config-
uration
software
this operation may be carried out from the PC using the
ELDES Configuration
software.
By default, event log is enabled. to disable/enable this feature, please refer to the following configuration methods.
Disable event log
EKB2
Menu path:
OK
→
iiii
→
OK
→
PRIMARY SettINGS
→
OK
→
eVeNt LOG
→
OK
→
DISABLe
→
OK
Value:
iiii
- 4-digit installer code.
EKB3/
EKB3W/
EWKB4
Enter parameter 36 and parameter status value:
36 0 #
Example:
360#
Enable event log
EKB2
Menu path:
OK
→
iiii
→
OK
→
PRIMARY SettINGS
→
OK
→
eVeNt LOG
→
OK
→
eNABLe
→
OK
Value:
iiii
- 4-digit installer code.
EKB3/
EKB3W/
EWKB4
Enter parameter 36 and parameter status value:
36 1 #
Example:
361#
ElDES
Config-
uration
software
this operation may be carried out from the PC using the
ELDES Configuration
software.