122
122 EN
ESIM384 Installation and Configuration Manual v1.1
27. SYStEM notIfICatIonS
By default, in case of a certain event, the system attempts to send an SMS text message to the first listed user phone number only. If the
user phone number is unavailable and the system fails to receive the SMS delivery report during 45 seconds, it will attempt to send the SMS
text message to the next listed user phone number, assigned to the same partition as the previous one. the user phone number may be
unavailable due to the following reasons:
•
mobile phone was switched off.
•
was out of GSM signal coverage.
the system will continue sending the SMS text message to the next listed user phone numbers in the priority order until one is available.
the system sends the SMS text message only once and will not return to the first user phone number if the last one was unavailable.
to change the SMS text message delivery algorithm, user can enable/disable the following parameters for certain events:
•
SMS Cascade enabled
- In case of specified event, system sends SMS text message to first user in a row. Only in case of failed attempt
(user phone is turned off or etc.) system will send to another user in a row until first successful attempt.
•
SMS Cascade disabled
- If ‘SMS Cascade’ option is disabled, the system simultaneously sends a certain SMS text message to all avail-
able users regardless if the previous one has received the SMS text message or not.
When using Dual-SIM feature, the Secondary SIM card is involved in the communication process. For more details, please refer to
31. DUal
SIM ManaGEMEnt.
the following table provides the description of system notifications by SMS text message sent to the user phone number.
Seq. no. Event
Description
1
System armed
SMS text message sent to the user regarding armed system.
2
System disarmed
SMS text message sent to the user about disarmed system.
3
General alarm
SMS text message sent to the user in case of system alarm occurrence.
4
Mains power loss/
restore
SMS text message sent to the user in case the mains power is lost or restored
5
Battery failed
SMS text message sent to the user in case the backup battery resistance is 2Ω or higher
(battery requires replacement).
6
Battery dead
or missing
SMS text message sent to the user in case the backup battery is not present or the battery voltage
runs below 5V.
7
Low battery
SMS text message sent to the user in case the backup battery voltage is 10.5V or lower.
8
Siren fail/restore
SMS text message sent to the user in case the siren is disconnected/broken or connected/fixed.
9
Date/time not set
SMS text message sent to the user in case system date and time is not set.
10
GSM connection failed SMS text message sent to the user in case the GSM connection is lost.
11
GSM/GPRS antenna
fail/restore
SMS text message sent to the user in case the GSM/GPRS antenna is disconnected/broken or
connected/fixed.
12
tamper alarm
SMS text message sent to the user in case of tamper violation. Indicated as
Tamper x
.
13
Communication bus
fail/restore
SMS text message sent to the user in case the RS485 device, such as keypad or zone and PGM
output expansion module is disconnected/broken or disconnected/broken or connected/fixed.
14
temperature info
SMS text message sent to the user in case of temperature deviation by the set values.
15
System started
SMS text message sent to the user on system startup.
16
Periodical info
Info SMS text message sent to the user periodically by the set values.
17
Wireless signal loss/
restore
SMS text message sent to the user in case the wireless signal is lost or restored.. Indicated as
No
wireless signal from wless-dev wless-id Tamper x and Wireless signal restored. From wless-dev
wless-id Tamper x
respectively. this notification does NOt apply to eWM1 device.
18
Unable to arm
SMS text message sent to the user in case the system denies arming due to existing violated zone
(-s)/tamper (-s)/other system fault (see
19.3. Wireless Signal Status Monitoring
).
19
CO level critical
SMS text message sent to the user in case the critical level 4 of carbon monoxide (CO) concentration
detected by eWF1CO is reached.
20
Report/Control zone
triggered
SMS text message sent to the user in case the Report/Control-type zone is triggered.
21
Zone autobypass
SMS text message sent to the user in case a violated zone is bypassed automatically.
22
eWM1 wireless signal
loss/restore
SMS text message sent to the user in case the wireless signal with eWM1 device is lost or restored.
Indicated as
No wireless signal from wless-dev wless-id Tamper x and Wireless signal restored.
From wless-dev wless-id Tamper x
respectively. this notification cannot be managed via eKB2.
23
Incoming SMS for-
warding
SMS text message sent to the user in case the SMS forwarding of the incoming SMS text messages
is enabled (see
27.3 SMS forward
). this notification can be managed via eKB3/eKB3W/eWKB4 and
ELDES Configuration
software only.
24
Wireless communica-
tion failed
SMS text message sent to the user in case the wireless signal failure is lasting for 20 minutes. this
event is a warning and does NOt cause an alarm (see
19.3. Wireless Signal Status Monitoring
).
25
RF jammer detected
SMS text message sent to the user in case the wireless signal is blocked by jammer.
26
Communication with
MS failed
SMS text message sent to user in case the system ends up with all unsuccessful attempts by all con-
nections to deliver data message to the monitoring station. this event can be managed using eLDeS
Configuration software only.
to enable/disable a certain system notification, please refer to the following configuration methods.