ESIM384 Installation and Configuration Manual v1.1
If all attempts by all set connections are unsuccessful, the system will wait until the delay time (by default – 1200 seconds) expires and
will attempt to transmit data to the monitoring station again starting with the primary connection.
Set delay after last
communication
attempt
EKB2
Menu path:
OK
→
iiii
→
OK
→
MS SettINGS
→
OK
→
DeLAY LASt AtteMPt
→
OK
→
aaapp
→
OK
Value:
iiii
– 4-digit installer code;
aaapp
– duration of delay after last attempt, range – [0...
65535] seconds.
EKB3/
EKB3W/
EWKB4
Enter parameter 69 and duration of delay after last attempt:
69 aaapp #
Value:
aaapp
– duration of delay after last attempt, range – [0... 65535] seconds.
Example:
69200#
ElDES
Config-
uration
software
this operation may be carried out from the PC using the
ELDES Configuration
software.
notE:
0 value disables delay after last communication attempt.
notE:
the system is fully compatible with Kronos Net/Kronos Lt/ Securithor monitoring station software for communication via GPRS or
LAN network. When using a different monitoring station software, eGR100 middleware, which is freeware and can be downloaded at
www.eldesalarms.com . Alternatively, you can use eSR100 digital receiver device.
30.2.1. GPrS network and Elan3-alarM
the system supports up to 3 server IP addresses for data transmission to the monitoring station via IP-based networks by GPRS network or
ethernet connection using eLAN3-ALARM device. the supported data formats are the following:
•
eGR100
•
Kronos
•
SIA IP
to set up the system for data transmission via GPRS network or ethernet using eLAN3-ALARM, please follow the basic configuration steps:
1.
enable MS Mode parameter (see
30. MonItorInG StatIon
).
2.
Set 4-character Main Account number (see
30. MonItorInG StatIon
). In addition, you may set the Account for up to 3 servers
individually.
3.
Set Server 1 IP address, which is a public IP address of eSR100 digital receiver, the machine running eGR100, Kronos or SIA IP-based
monitoring station software. In addition, you can set up to 3 server IP addresses in total.
4.
Set Server 1 port, which is a port of eSR100 digital receiver, the machine running eGR100, Kronos or SIA IP-based monitoring station
software. In addition, you may set the port for up to 3 servers individually.
5.
Select tCP or UDP protocol for Server 1. In addition, you may select the protocol for up to 3 servers individually.
6.
Select data format for Server 1: eGR100, Kronos or SIA IP. In addition, you may select the data format for up to 3 servers individually.
7.
In case eGR100 is selected, set 4-digit Unit ID numbers. Unit ID number can be identical to Account number. In addition, you may set
the Unit ID for up to 3 servers individually.
8.
When using GPRS network connection, it is necessary to set up APN, user name and password provided by the GSM operator. De-
pending on the GSM operator, only APN might be required to set up .
9.
In case eGR100 is selected, for security reasons it is highly recommended to set up the 4-digit encryption key matching the 4-digit
encryption key set up in eGR100 middle-ware. In case of encryption key mismatch, the data delivered by the system will be rejected
by eGR100 middle-ware. By default, the encryption key is not used.
10.
In case more than one server IP address is set up, you may wish to enable parallel data transmission to all IP addresses simultaneous-
ly. By default, this feature is disabled, therefore the system will switch to the next IP address (if set up and selected in the connection
priority sequence) in the event of failed connection with the previous server.
For detailed step-by-step instructions on how to establish the communication between eSIM384 alarm system and eGR100 middleware,
please refer to the middleware’s HeLP file.
Set server IP address
SMS
SMS text message content:
Server 1:
ssss_SetGPRS:IP:add.add.add.add
Value:
ssss
– 4-digit SMS password;
add.add.add.add
– server IP address.
Example:
1111_SETGPRS:IP:65.82.119.5