ESIM384 Installation and Configuration Manual v1.1
30.2.3. PStn
the system supports up to 3 monitoring station phone numbers for communication with the alarm system by PStN communication meth od
using Ademco Contact ID data format. tel. Number 1 is mandatory, the other two can be used as backup phone numbers and are not neces-
sary. the supported phone number formats are the following:
•
International (with 00)
– the phone numbers must be entered starting with 00 and an international country code in the following
format: 00[international code][area code][local number], example for UK:
0044170911XXXX1
. this format can be used when setting
up the phone number by eKB2/eKB3/eKB3W/eWKB4 keypad and
ELDES Configuration
software.
•
local
– the phone numbers must be entered starting with an area code in the following format: [area code][local number], example
for UK:
0170911XXXX1
. this format can be used when setting up the phone number by eKB2/eKB3/eKB3W/eWKB4 keypad and
EL-
DES Configuration
software.
to set up the system for data transmission via PStN, please follow the basic configuration steps:
1. enable MS Mode parameter (see
30. MonItorInG StatIon
).
2. Set 4-digit Main Account number (see
30. MonItorInG StatIon
).
3. Set tel. Number 1... 3.
Set monitoring station
phone number
EKB2
Menu path:
OK
→
iiii
→
OK
→
MS SettINGS
→
OK
→
PStN SettINGS
→
OK
→
teL. NUMBeR 1... 3
→
OK
→
ttteeellnnuumm
→
OK
Value:
iiii
– 4-digit installer code;
ttteeellnnuumm
– up to 15 digits monitoring station
phone number.
EKB3/
EKB3W/
EWKB4
Enter parameter 58, phone number slot and phone number:
58 ps ttteeellnnuumm #
Value:
ps
– phone number slot, range – [01... 03];
ttteeellnnuumm
– up to 15 digits monitor-
ing station phone number.
Example:
58020044170911XXXX1#
ElDES
Config-
uration
software
this operation may be carried out from the PC using the
ELDES Configuration
software.
Delete monitoring
station phone number
EKB2
Menu path:
OK
→
iiii
→
OK
→
MS SettINGS
→
OK
→
PStN SettINGS
→
OK
→
teL. NUMBeR 1... 3
→
OK
→
OK
Value:
iiii
– 4-digit installer code.
ElDES
Config-
uration
software
this operation may be carried out from the PC using the
ELDES Configuration
software.
By default, if the initial attempt to transmit data to the monitoring station’s tel Number 1 via PStN method is unsuccessful, the system
will make up to 2 additional attempts. After all unsuccessful attempts, the system will switch to the next phone number that follows in
the sequence and will make up to 2 additional attempts if the initial attempt was unsuccessful. If all attempts to all phone numbers are
unsuccessful, the system will switch to next backup connection that follows in the sequence and will attempt to transmit data until it is
successfully delivered to the monitoring station.
Set attempts
EKB2
Menu path:
OK
→
iiii
→
OK
→
MS SettINGS
→
OK
→
PStN SettINGS
→
OK
→
AtteMPtS
→
OK
→
at
→
OK
Value:
iiii
– 4-digit installer code;
at
– number of attempts, range – [1... 10].
EKB3/
EKB3W/
EWKB4
Enter parameter 91 and number of attempts:
91 at #
Value:
at
– number of attempts, range – [01... 10].
Example:
9108#
ElDES
Config-
uration
software
this operation may be carried out from the PC using the
ELDES Configuration
software.
Alternatively, the phone number entries can be treated as phone numbers for receiving calls in case of alarm. For more details on how this
method operates, please refer to
17. alarM InDICatIonS anD notIfICatIonS for USEr.
to enable/disable this feature, please refer to the following configuration method.