151
151
EN
ESIM384 Installation and Configuration Manual v1.1
Set attempts
EKB2
Menu path:
Server 1:
OK
→
iiii
→
OK
→
MS SettINGS
→
OK
→
IP SettINGS
→
OK
→
SeRVeR IP
→
OK
→
IP
AtteMPtS
→
OK
→
att
→
OK
Server 2:
...
→
SeRVeR2 IP
→
OK
→
IP AtteMPtS
→
OK
→
att
→
OK
Server 3:
...
→
SeRVeR3 IP
→
OK
→
IP AtteMPtS
→
OK
→
att
→
OK
Value:
iiii
– 4-digit installer code;
att
– number of attempts, range – [1... 255].
EKB3/
EKB3W/
EWKB4
Enter parameter 68 and number of attempts/parameter 96, parameter number
and number of attempts:
Server 1:
68 att #
Server 2:
96 08 att #
Server 3:
96 09 att #
Value:
att
– number of attempts, range – [01... 255].
Example:
6809#
ElDES
Config-
uration
software
this operation may be carried out from the PC using the
ELDES Configuration
software.
to report the online status, the system periodically transmits (by default – every 180 seconds) test event data message (ping) to the mon-
itoring station via GPRS network or ethernet.
Set test period
EKB2
Menu path:
Server 1:
OK
→
iiii
→
OK
→
MS SettINGS
→
OK
→
IP SettINGS
→
OK
→
SeRVeR IP
→
OK
→
teSt
PeRIOD
→
OK
→
tteessttpp
→
OK
Server 2:
...
→
SeRVeR2 IP
→
OK
→
teSt PeRIOD
→
OK
→
tteessttpp
→
OK
Server 3:
...
→
SeRVeR3 IP
→
OK
→
teSt PeRIOD
→
OK
→
tteessttpp
→
OK
Value:
iiii
– 4-digit installer code;
tteessttpp
– test period, range – [0... 65535] seconds.
EKB3/
EKB3W/
EWKB4
Enter parameter 46 and number of attempts/parameter 96, parameter number
and number of attempts:
Server 1:
46 tteessttpp #
Server 2:
96 10 tteessttpp #
Server 3:
96 11 tteessttpp #
Value:
tteessttpp
– test period, range – [0... 65535] seconds.
Example:
46120#
ElDES
Config-
uration
soft-
ware
this operation may be carried out from the PC using the
ELDES Configuration
software.
notE:
0 value disables test period. However, disabling the test period is HIGHLY UNReCOMMeNDeD.
Unit ID is a 4-digit number (By default – 0000) required to identify the alarm system unit by eGR100 middle-ware. It is ReCOMMeNDeD to
change the default Unit ID before using eGR100.
Set unit ID
EKB2
Menu path:
Server 1:
OK
→
iiii
→
OK
→
MS SettINGS
→
OK
→
IP SettINGS
→
OK
→
SeRVeR IP
→
OK
→
UNIt
ID
→
OK
→
unid
→
OK
Server 2:
...
→
SeRVeR2 IP
→
OK
→
UNIt ID
→
OK
→
unid
→
OK
Server 3:
...
→
SeRVeR3 IP
→
OK
→
UNIt ID
→
OK
→
unid
→
OK
Value:
iiii
– 4-digit installer code;
unid
– 4-digit unit ID number.
EKB3/
EKB3W/
EWKB4
Enter parameter 47 and unit ID number/parameter 96, parameter number and unit
ID number:
Server 1:
47 unid #
Server 2:
96 14 unid #
Server 3:
96 15 unid #
Value:
unid
– 4-digit unit ID number.
Example:
472245#