19.5.2. Keys functionality
descrIptIon
1
2
3
4
5
6
7
8
9
*
0
#
40
front SIDE
1st character for staY-arming
1st character for violated zone bypass and bypassed
zone activation
1st character for configuration mode activation or
deactivation
1st character for system fault list indication / 1st
character for violated high-numbered zone indication
/ 1st character for violated tamper indication
0
9
command typing
1
2
Keypad partition switch
*
clear typed in characters
typed in command confirmation
19.5.3. Wireless Communication, Sleep Mode and Back-light timeout
Once the wireless device is paired, it will attempt to exchange data with eSIM384 system. the communication process follows this pattern:
1. Due to battery power saving reasons, most of the time eKB3W/eWKB4 keypad operates in sleep mode and periodically wakes up (by
default - every 5 minutes) to transmit the supervision signal, identified as test time, to the eSIM384 system. However, when the keypad
wakes up, it will NOt activate its buzzer and/or the LeD indicators.
2. When any eKB3W/eWKB4 key is pressed, the keypad LeD indicators and the back-light will activate for a set up period of time (by default -
10 seconds), identified as Back-light timeout. During the Back-light timeout, the test time will automatically switch to 2 seconds period
allowing to indicate system alarms, faults and arm/disarm process on the eKB3W/eWKB4 keypad if it is assigned to the same partition as
the one that is violated or being armed/disarmed (see
23. PartItIonS)
.
3. the Back-light timeout will expire after 10 seconds (by default) of eKB3W/eWKB4 idling. When the Back-light timeout expires, the key-
pad will light OFF the LeD indicators and the back-light and return to sleep mode. Meanwhile:
a) if a zone or tamper, which is of the associated eKB3W/eWKB4 keypad, is violated, eKB3W/eWKB4 will instantly wake up and initiate
the Back-light timeout. Meanwhile the keypad buzzer will emit short beeps and the LeD indicators will light ON indicating the violated
zone or tamper number.
b) if a zone or tamper, which is not of the associated eKB3W/eWKB4 keypad, is violated, eKB3W/eWKB4 keypad will NOt wake up and will
NOt initiate the Back-light timeout as well as the buzzer will NOt emit short beeps and the LeD indicators will NOt light ON.
to set a different Back-light timeout value, please refer to the following configuration method:
Set Back-light
timeout
ElDES
Config-
uration
software
this operation may be carried out from the PC using the
ELDES Configuration
software.
For more details and how to set a different test time value, please refer to
ELDES Configuration
software.
notE:
By default, the keypad zone and tamper is enabled, therefore a resistor supplied with the eKB3W/eWKB4 keypad must be connect-
ed to the keypad zone terminal and the tamper switch must be properly pressed in when inserting the keypad into the holder.
notE:
to wake up the keypad it is highly recommended to press the [*] key in order not to enter any unnecessary character. If other
character is pressed it is already counted in characters sequence meant for arming/disarming or configuration.