180
180 EN
ESIM384 Installation and Configuration Manual v1.1
tErM
DESCrIPtIon
trigger
An event which causes another event or action, often initiating a signal generation or
acquisition.
Volt
the unit of voltage or electromotive force
Voltage
the amount of energy available to move a certain number of electrons from one point to another in
an electric circuit
Wireless device
Devices that communicate without connecting wires or other material contacts.
Zone
Detection devices such as motion detectors and door contacts are connected to the alarm system’s
zone terminals.
Zone state/status
Zone status is a position of a certain zone being enabled or disabled. Meanwhile, zone state points out
the condition of a certain zone, which can either be violated (i.e. In case of alarm) or restored.
39. EKB3/EKB3W/EWKB4 CoMManDS - aPPEnDIX 2
CoMManD
DEfInItIon
CoDE
CoMManD
ValUE
EXaMPlE
Arm the system in Stay mode
uumm
uumm – 4-digit user/
master code.
1111
Bypass individual zone /
Activate Bypassed zone
nn uumm#
nn – zone number, range –
[01... 80]; uumm – 4-digit
user/master code.
091111#
Activate/deactivate
Configuration mode
iiii #
ii ii– 4-digit installer code.
1470#
Set master code
A)
0 vvvv 01 mmmm #
B) 63 vvvv mmmm #
(only whenConfiguration
Mode is activated).
A) vvvv – 4-digit existing
master code; mmmm - 4-digit
new master code; range -
[0000... 9999].
B) vvvv – 4-digit existing
master code; mmmm – 4-digit
new master code, range –
[0000... 9999].
A) 01111012222#
B) 6311112222#
Set user code
0 mmmm us uuuuu #
mmmm - 4-digit master code;
us - user code slot, range -
[02... 30].
0111109#
Delete user code
0 mmmm us #
us - user code slot, range -
[02... 10]; mmmm - 4-digit
master code.
3081111#
Set Duress code
3 us mmmm #
us - user code slot, range -
[02... 10]; mmmm - 4-digit
master code.
4041111#
Set user/master
code partition
User code: 5 us pv mmmm
#
Master code: 5 01 pv
mmmm #
us - user code slot, range
- [02... 30]; pv – partition val-
ue, range - [01... 15] ;mmmm
- 4-digit master code.
504081111#
Switch keypad partition
(eKB3/ eKB3W/eWKB4)
Hold the [1]... [4] key and
release it after 3 short beeps
(for eKB3 keypad) ;
Hold the [1]... [2] key and
release it after 3 short beeps
(for eKB3W/eWKB4 keypads)
[1]... [4] key – partition num-
ber 1... 4 respectively.
[1]... [2] key – partition num-
ber 1... 2 respectively.
Arm the system/ Dis-
arm the system and
turn OFF the alarm
uumm
uumm – 4-digit user/
master code.
2222