170
170 EN
ESIM384 Installation and Configuration Manual v1.1
33. SErVICE MoDE
the system comes equipped with Service mode allowing to carry out system maintenance tasks, such as detection device replacement,
tamper switch installation, wireless device battery replacement without causing zone or tamper alarm when Service mode is activated. to
activate/deactivate Service mode, please refer to the following configuration methods:
activate Service
mode
SMS
SMS text message content:
ssss_SeRVICeMODe:ON
Value:
ssss
- 4-digit SMS password.
Example:
1111_SERVICEMODE:ON
EKB2
Menu path:
OK
→
iiii
→
OK
→
SeRVICe MODe
→
OK
→
eNABLe
→
OK
Value:
iiii
– 4-digit installer code.
EKB3/
EKB3W/
EWKB4
Enter parameter 67 and parameter status value:
67 1 #
Example:
671#
ElDES
Config-
uration
software
this operation may be carried out from the PC using the
ELDES Configuration software.
Deactivate Service
mode
SMS
SMS text message content:
ssss_SeRVICeMODe:OFF
Value:
ssss
- 4-digit SMS password.
Example:
1111_SERVICEMODE:OFF
EKB2
Menu path:
OK
→
iiii
→
OK
→
SeRVICe MODe
→
OK
→
DISABLe
→
OK
Value:
iiii
– 4-digit installer code.
EKB3/
EKB3W/
EWKB4
Enter parameter 67 and parameter status value:
67 0 #
Example:
670#
ElDES
Config-
uration
software
this operation may be carried out from the PC using the
ELDES Configuration software
.
notE:
Alternatively, the Service mode automatically deactivates when 1-hour timeout period expires or after arming the system.
34. rEMotE SYStEM rEStart
In some critical situations, a system restart may be required. to remotely carry out system restart, please refer to the following configura-
tion method.
restart the system
SMS
SMS text message content:
ssss_ReSet
Value:
ssss
– 4-digit SMS password.
Example:
1111_RESET