77
77
EN
ESIM384 Installation and Configuration Manual v1.1
18.6.2. Schedulers
the system supports up to 16 schedulers that allow the PGM outputs to operate or automatically arm/disarm a certain partition (all par-
titions) according to the day of the week and time. When the scheduler, which includes the set weekday and time, is selected, the PGM
output will operate or the system will arm/disarm according to it. each scheduler includes the following parameters:
•
always
– the scheduler is not in use.
•
at specified time
– Determines whether weekday and time settings are enabled:
•
Start time
– Determines the point in time when the PGM output or automatic arm/disarm action can be initiated for Scheduler
starts event.
•
End time
– Determines the point in time when the PGM output action can be initiated for Scheduler ends event
•
on weekdays
– Determines days in week when the PGM output or automatic arm/disarm action is valid.
18.6.3. additional Conditions
Additional condition narrows down the chances for a determined automatic PGM output operation to be carried out. If this feature is en-
abled, the PGM output will become dependent on one more system event that must be occurred prior or must occur after the aforemen-
tioned system event. the PGM output will not operate until the chain of system events meets the set values:
•
System armed
– System is armed in a determined partition ranging from 1 to 4 or any partition.
•
System disarmed
– System is disarmed in a determined partition ranging from 1 to 4 or any partition.
•
Zone violated
– A determined zone ranging from Z1 to Z80 is violated.
•
Zone restored
– A determined zone ranging from Z1 to Z80 is restored.
Example:
PGM output C1 is set to be turned ON when zone Z6 is violated. The additional condition feature is enabled and set to allow this
action to be carried out only if system’s Partition 2 is disarmed. It means that the PGM output C1 will be turned ON when zone Z6 is violated,
but only if system’s Partition 2 is disarmed.
Manage PGM output
control by event &
scheduler
ElDES
Config-
uration
software
this operation may be carried out from the PC using the
ELDES Configuration
software.
attEntIon:
If the date and time are not set, the system will NOt be able to automatically control the PGM outputs. For more details on how
to set date and time, please refer to
9. DatE anD tIME
.
notE:
When both - a system event is determined and a scheduler is selected, the PGM output will operate only if the determined event has
occurred in the system during the scheduled time period.
notE:
When PGM output action is selected as pulse, the PGM output will turn ON or turn OFF for a set period of time based on the PGM
output state set up (ON or OFF) for system startup.
18.7. Wireless PGM output type Definitions
•
output
– Operates as normal PGM output that can be controlled by the user or automatically by event and scheduler. Normally, this
type is used for any device or relay.
•
Siren
– Operates as siren output that automatically activates during alarm. typically, this type is used for bell/siren connected to eW2
wireless device.
Set output type for
individual wireless
PGM output
ElDES
Config-
uration
software
this operation may be carried out from the PC using the
ELDES Configuration
software.