Setting the Mode Switch
DLE28-MA User’s Guide
C-3
After changing the position of switch 6 and restarting the module, the
DLE28-MA request a new image download until they either receive a
new image or the RESET button on the front panel is pressed. When
the RESET button is pressed, the DLE28-MA continue trying to
contact a BootP server, but will time out in approximately one minute.
If the module times out, the image is downloaded from its FLASH
memory.
•
Switch 7 – Clear NVRAM. Changing the position of this switch resets
NVRAM on the next power up. ALL user-entered parameters, such as
IP addresses, subnet masks, SNMP traps, and bridging functions are
restored to their factory default settings.
•
Switch 8 – Reset Password/Community Strings. Changing the position
of this switch clears only the user-entered passwords stored in
NVRAM, and restores the default passwords. Once the DLE28-MA
are reset, the passwords can either be reentered or the default
passwords (Public and ENTER) may be used.
After changing the position of switch 6, DO NOT reapply power
to the chassis until there is a station acting as a BootP server,
which contains the image file.
Do not change the position of switch 8 unless it is necessary to
reset the module super-user configured passwords to their
factory default settings.