General Configuration Screen
DLE28-MA User’s Guide
5-53
3.
Use the arrow keys to highlight YES. Press ENTER.
4.
If you the port was enabled, proceed to Section 5.15.12. If the port was
disabled, use the arrow keys to highlight SAVE at the bottom of the
screen, then press ENTER. When the message “SAVED OK”
displays, the edits are saved.
5.15.12 Changing the Com Port Application
After enabling the COM port as described in Section 5.15.11, you can
select one of the applications supported by the COM port: LM or UPS can
be selected. The default application is LM.
To change the COM port application:
1.
Use the arrows keys to highlight the Application field.
2.
Use the SPACE bar or BACKSPACE to step through the available
settings until the operation you require appears. Table 5-3 lists the
available settings and their corresponding applications.
3.
Press ENTER to accept the application.
4.
Use the arrow keys to highlight SAVE at the bottom of the screen, then
press the ENTER key.
5.
When the message “SAVED OK” displays, the edits that were made
are saved.
If the DLM6C-AA chassis has been configured with a valid IP
address this screen will not appear. When the chassis is
assigned a valid IP address all the interface modules installed
share this same address.
I
Exiting without saving causes the message “NOT SAVED --
PRESS SAVE TO KEEP CHANGES” to appear. Exiting without
saving causes all edits to be lost.
Table 5-3. COM Port Application Settings
Setting
Application
LM
Local Management Session
UPS
APC Power Supply SNMP Proxy