Chapter 5: Local Management
5-54
DLE28-MA User’s Guide
5.15.13 Clearing NVRAM
Clearing NVRAM allows the user to clear all user-entered parameters,
such as IP address and Community Names from NVRAM.
Clear NVRAM as follows:
1.
Use the arrow keys to highlight the Clear NVRAM field.
2.
Use the SPACE bar to toggle the field to YES.
3.
Use the arrow keys to highlight SAVE at the bottom of the screen.
4.
Press ENTER. The warning shown in Figure 5-20 displays.
I
When the COM port is configured to perform the UPS
application, all future Local Management connections must be
made by establishing a Telnet connection to the module.
Ensure that the module has a valid IP address before saving
changes to the COM port application. If the module does not
have a valid IP address and the changes are saved, refer to
Appendix C for instructions on clearing NVRAM in order to
reestablish COM port communications.
I
Clearing NVRAM will result in the loss of all user-entered
parameters. Do not proceed unless this procedure is
completely understood.