Chapter 21: Snapshots
179
Parameter Matrix
The parameter matrix is a scrollable grid in which you can safe
parameters and channels. You can undo and redo parameter
matrix operations.
Parameters are represented in the columns of the parameter
matrix; channels are listed along the left side in rows.
Clicking in the grid enables safe status for that parameter on
that channel. Parameter and Channel grid icons provide
shortcuts to “safe all” parameters in a single-click, and to safe
entire channels. Clicking these icons lets you quickly toggle
recall safe status for entire columns and rows. You can also use
the master grid icon located in the upper left most corner to
toggle the entire grid.
The display state of the Parameter and Channel grid icons in-
dicate safe status for that column or row as follows:
None
A dark Parameter or Channel grid icon indicates that no
items in that column or row are safe enabled.
Some
A dark triangle inside a lit blue circle indicates that at
least one item in that column or row is safe enabled.
All
A lit (white) triangle indicates that all items in that column
or row are safe enabled.
Channel Safe Controls
The CHANNEL SAFE column mirrors the SAFE switch on the
console and on-screen. Controls in the CHANNEL SAFE col-
umn are not part of the parameter matrix; they function
in ad-
dition to
the parameter matrix and act as a global “all channel”
setting or override. As a result, you do not need to enable any
CHANNEL SAFE settings to use the Recall Safe parameter ma-
trix.
Using Recall Safe
To access the Recall Safe page:
1
Do one of the following:
• Go to the Snapshots page and click the Recall Safe tab.
– or –
• Double-press the Snapshot View switch until the Recall
Safe tab is displayed.
2
Click a channel type tab to display the desired channels.
To safe individual parameters on specific channels:
■
Click in the grid at the intersection of the appropriate pa-
rameter (column) and channel (row). A blue dot appears, in-
dicating a parameter is safed.
To safe multiple parameters or channels at a time:
■
Click and drag in a column, across a row, or at an angle.
Parameter matrix for Recall Safe
Display states for grid icons in Recall Safe
Parameters
Channels
Channel grid icons
Parameter grid icons
Channel Safe
None
Some
All
Grid master icon
For more information, see “Automation Safing Channels”
on page 181.
Enabling recall safe for channel 1 fader
Click
Summary of Contents for D-Show Profile
Page 10: ...D Show Profile Guide x ...
Page 11: ...Part I Overview and Installation ...
Page 12: ......
Page 16: ...D Show Profile Guide 6 ...
Page 32: ...D Show Profile Guide 22 ...
Page 33: ...Part II System Description ...
Page 34: ......
Page 50: ...D Show Profile Guide 40 ...
Page 58: ...D Show Profile Guide 48 ...
Page 67: ...Part III Signal Routing ...
Page 68: ......
Page 94: ...D Show Profile Guide 84 ...
Page 102: ...D Show Profile Guide 92 ...
Page 110: ...D Show Profile Guide 100 ...
Page 134: ...D Show Profile Guide 124 ...
Page 135: ...Part IV Processing ...
Page 136: ......
Page 144: ...D Show Profile Guide 134 ...
Page 171: ...Part V Shows ...
Page 172: ......
Page 180: ...D Show Profile Guide 170 ...
Page 204: ...D Show Profile Guide 194 ...
Page 227: ...Part VI Specifications ...
Page 228: ......
Page 236: ...D Show Profile Guide 226 D Show Output Signal Flow Diagram Version 1 3 07 07 05 ...
Page 245: ...Part VII Reference ...
Page 246: ......
Page 258: ...D Show Profile Guide 248 ...
Page 269: ......