DVP15MC11T Operation Manual
_8
Variable name
Data type
Initial value
SEMA1_Q
BOOL
Timing Chart:
Case 1
:
When SEMA1_CLAIM is TRUE, SEMA1_Q is TRUE in the second period. When
SEMA1_RELEASE is TRUE, SEMA1_Q changes to FALSE immediately.
Case 2
:
When SEMA1_CLAIM is TRUE, SEMA1_Q is TRUE in the second period no matter
whether SEMA1_RELEASE is TRUE or FALSE.
1
SEMA
EN
ENO
CLA IM
Q
S EMA1
RE LEAS E
SEMA 1_EN
S EMA1_ CL AIM
SEMA1 _RELEA SE
SE MA1_Q
S EMA1_ CL AIM
SEMA1 _RELEA SE
SEMA 1_Q
Ca se 1
Ca se 2
8-16