Chapter 12 Troubleshooting
11
Wiring Figure
Mode 0 and mode 1
Mode 0: The external signal triggers I point of DVP15MC11T and the position capture is conducted
through the rising edge of the input point specified by
TriggerInput
. The captured position is
converted from the number of pulses the external encoder port of the controller receives
through axis parameters.
Mode 1: The external signal triggers I point of DVP15MC11T and the position capture is conducted
through the falling edge of the input point specified by
TriggerInput
. The captured position is
converted from the number of pulses the external encoder port of the controller receives
through axis parameters.
Mode 2
The external signal triggers the high-speed input point: DI7 of the servo drive. The position captured is
converted from the number of pulses which the servo motor feeds back to the servo drive through axis
parameters.