DVP15MC11T Operation Manual
_8
Precautions for Correct Use
The input variables are not allowed to omit. An error will occur during the compiling of the software if
any input variable is omitted. But the output variable is allowed to omit.
The input value of
In2
can not be 0. In other words, the divisor in the division operation can not be 0.
The value of
Out
will be 0 if the value of
In2
is 0.
Programming Example
The data types of variables
MODTURNS
_In1, MODTURNS
_In2 are
both
REAL
and
Out1
is DINT.
The values of
MODTURNS
_In1
and
MODTURNS
_In2
are 800.23 and 360.0 respectively. The
value of
Out1
is 2 when
MODTURNS
_EN
changes to TRUE.
The variable table and program
Variable name
Data type
Current value
MODTURNS_EN
BOOL
TRUE
MODTURNS _In1
REAL
800.23
MODTURNS _In2
REAL
360.0
Out1
DINT
2
1
MO DTURNS
EN
E NO
I n1
Out
I n2
MO DTURNS_EN
MO DTURNS_I n1
MO DTURNS_I n2
Out 1
8-70