Chapter 8 Logic Instructions
8_
The value of In
The value of Out
In<0
In+BiasN
In=0
0
In>0
In+BiasP
The instruction allows input parameters
BiasN
,
In
and
BiasP to
connect the variables of different
data types. When
BiasN
,
In
and
BiasP
are the variables of different data types, the calculation is
performed with the data type which can contain the range of the values of
BiasN
,
In
and
BiasP
. For
example, if the data type of
BiasN
is INT and the data types of
In
and
BiasP
are DINT, the data type
of
Out
is DINT.
The instruction allows the input parameters and the output parameter to connect the variables of
different data types. But the length of the data type of the output variable must contain the length of
the variables that the input parameters
connect. Otherwise, an error will occur during the compiling
of the software.
Precautions for Correct Use
The input variables are not allowed to omit. An error will occur during the compiling of the software if
the input variables are omitted. But the output variable is allowed to omit.
When the value of
BiasN
is larger than
BiasP,
the instruction will still be executed normally.
Programming Example
The data types of ZONE_BiasN, ZONE_In and ZONE_BiasP are INT, INT and DINT and the data
type of Out1 is DINT. When ZONE_EN is TRUE, the value of Out1 is 0 if the values of ZONE_BiasN,
ZONE_In and ZONE_BiasP are 1, 0 and 100 as shown in the following table Variable 1. If the
values of ZONE_BiasN, ZONE_In and ZONE_BiasP are 2, 50 and 100, the value of Out1 is 150
(150 = 50 + 100) as shown in the following table Variable 2. If the values of ZONE_BiasN, ZONE_In
and ZONE_BiasP are 50, -10 and 100, the value of Out1 is 40 (40 = - 10 + 50) as shown in the
following table Variable 3.
Variable 1
Variable name
Data type
Current value
ZONE_EN
BOOL
TRUE
ZONE_BiasN
INT
1
ZONE_In
INT
0
ZONE_BiasP
DINT
100
Out1
DINT
0
Variable 2
Variable name
Data type
Current value
ZONE_EN
BOOL
TRUE
ZONE_BiasN
INT
2
ZONE_In
INT
50
ZONE_BiasP
DINT
100
Out1
DINT
150
Variable 3
Variable name
Data type
Current value
ZONE_EN
BOOL
TRUE
ZONE_BiasN
INT
50
ZONE_In
INT
- 10
ZONE_BiasP
DINT
100
Out1
DINT
40
8-147
Summary of Contents for DVP15MC11T
Page 9: ...Memo viii...
Page 15: ...DVP15MC11T Operation Manual _2 MEMO 2 4...
Page 71: ...DVP15MC11T Operation Manual _7 Memo 7 10...
Page 81: ...DVP15MC11T Operation Manual _8 Timing Chart F_TRG_CLK F_TRG_Q 8 10...
Page 158: ...Chapter 8 Logic Instructions 8_ The program 1 ASIN EN ENO In Out ASIN_EN ASIN_In Out1 8 87...
Page 249: ...DVP15MC11T Operation Manual _8 8 178...
Page 285: ...DVP15MC11T Operation Manual _8 Memo 8 214...
Page 323: ...DVP15MC11T Operation Manual 10 MEMO 10 34...
Page 549: ...DVP15MC11T Operation Manual A MEMO A 16...