DVP15MC11T Operation Manual
_9
Serial No
Parameter Name
Function
Data Type
Default
Value
As mentioned above,
UnitsPerRotation
is set to 1 and the ball screw will move 50 mm at the velocity
1mm/s, acceleration 2mm/ s
2
and change rate of acceleration 1mm/s
3
after the following
MC_MoveRelative is executed.
The variable table and program
Variable name
Data type
Initial value
Rel
MC_MoveRelative
Rel_Ex
BOOL
FALSE
Rel_BM
MC_Buffer_Mode
0
Rel_Done
BOOL
Rel_Bsy
BOOL
Rel_Act
BOOL
Rel_Abt
BOOL
Rel_Err
BOOL
Rel_ErrID
WORD
15
Homing Mode
Set the homing mode of the servo drive;
range: 1~ 35.
See appendix D for more details.
UINT
1
16
Speed 1
The speed from starting homing to finding
the home switch; Unit: rpm, setting range:
1-2000 rpm
UDINT
20
Speed 2
The speed from finding the home switch to
reaching the mechanical home; Unit: rpm,
setting range: 1-500 rpm
UDINT
10
Se rvo mot or
Cou pl in g
Sc rew pa rt
Ge ar bo x
Sc rew
s haft
Cou p li ng
1 :2
In p ut
Ou tpu t
1
Rel_Bsy
Rel_Ac t
Rel_Abt
Rel_Err
Rel_ErrID
Rel_Done
Rel_Ex
Ax is1
50. 0
1. 0
2. 0
2. 0
1
Rel_BM
MC_Mov eRelative
Axis
Done
Rel
Ex ecute
ContinuousUpdate
Busy
Activ e
Dis tanc e
CommandAborted
Error
ErrorID
Acc elerat ion
Deceleration
Jerk
BufferMode
Velocity
9-4
Summary of Contents for DVP15MC11T
Page 9: ...Memo viii...
Page 15: ...DVP15MC11T Operation Manual _2 MEMO 2 4...
Page 71: ...DVP15MC11T Operation Manual _7 Memo 7 10...
Page 81: ...DVP15MC11T Operation Manual _8 Timing Chart F_TRG_CLK F_TRG_Q 8 10...
Page 158: ...Chapter 8 Logic Instructions 8_ The program 1 ASIN EN ENO In Out ASIN_EN ASIN_In Out1 8 87...
Page 249: ...DVP15MC11T Operation Manual _8 8 178...
Page 285: ...DVP15MC11T Operation Manual _8 Memo 8 214...
Page 323: ...DVP15MC11T Operation Manual 10 MEMO 10 34...
Page 549: ...DVP15MC11T Operation Manual A MEMO A 16...