DVP15MC11T Operation Manual
_8
Precautions for Correct Use
The input variable is not allowed to omit. An error will occur during the compiling of the software if
the input variable is omitted. But the output variable is allowed to omit.
Programming Example
The data types of variables
COS _In
and
Out1
are INT and LREAL respectively. The value of
Out1
is -0.839071529076452
if the value of
COS _In
is 10 when
COS _EN
changes to TRUE. The value
of
Out1
is -0.839071529076452 as
COS _In
is -10.
Variable 1
Variable name
Data type
Current value
COS_EN
BOOL
TRUE
COS_In
INT
10
Out1
LREAL
-0.839071529076452
Variable 2
Variable name
Data type
Current value
COS_EN
BOOL
TRUE
COS_In
INT
-10
Out1
LREAL
-0.839071529076452
The program
1
COS
EN
ENO
In
Out
CO S_E N
COS_ In
O ut1
8-82