DVP15MC11T Operation Manual
_6
DVP15MC11T
Ground
Safety circuit
6.2
Input Point and Output Point Wiring
6.2.1
Function that Input Points Support
There are 16 input points which support external interrupt and filter functions in DVP15MC11T. In addition,
the input points can be used to capture the encoder position.
Refer to the explanation of the DMC_TouchProbe instruction for details on position capture.
The work principle of the input filter
The input filter filters short pulse signals via the 16 I points I0~I7 and I10~I17 to reduce the influence of
the input interference signals. Increasing the filter value can decrease the vibration of input signals or the
influence from external interference.
Input filter time: t=31us *
(
0~255
)
. So the filter time is a multiple of 31us and 0 is the default value. The
input filter time can be set through the software.
When there is the set filter:
When the filter time is set to t (us), the signal is valid if the ON or OFF time of the input signal is
greater than t (us). If the ON or OFF time of input signal is less than t (us), the signal will be
eliminated. The input signal left after being filtered will be input after being delayed by t (us).
t(us)
t( us)
Input
signals
Input signal
s
after being filte
d
re
Figure 6.2.1.1
When there is no filter set:
The input signals have no change when no filter time is set.
Figure 6.2.1.2
Inp ut
In put signa ls
withou t filter set
6-4
Summary of Contents for DVP15MC11T
Page 9: ...Memo viii...
Page 15: ...DVP15MC11T Operation Manual _2 MEMO 2 4...
Page 71: ...DVP15MC11T Operation Manual _7 Memo 7 10...
Page 81: ...DVP15MC11T Operation Manual _8 Timing Chart F_TRG_CLK F_TRG_Q 8 10...
Page 158: ...Chapter 8 Logic Instructions 8_ The program 1 ASIN EN ENO In Out ASIN_EN ASIN_In Out1 8 87...
Page 249: ...DVP15MC11T Operation Manual _8 8 178...
Page 285: ...DVP15MC11T Operation Manual _8 Memo 8 214...
Page 323: ...DVP15MC11T Operation Manual 10 MEMO 10 34...
Page 549: ...DVP15MC11T Operation Manual A MEMO A 16...