Chapter 12 Troubleshooting
11
Case 4
:
In the course of execution of the instruction,
Done
changes to TRUE when the instruction
execution is completed after
Execute
changes from TRUE to FALSE. Meanwhile,
Busy
and
Active
change to FALSE and one period later,
Done
changes to FALSE.
Function
MC_MoveAbsolute is used to make the axis move to the specified absolute target position at the set
speed, acceleration and deceleration.
The start axis position is 10000 when MC_MoveAbsolute instruction is executed. The axis will move
reversely when
Position
>0 (5000). See the figure below when
Position
is 5000.
The axis will move reversely when
Position
<0 (-5000). See the figure below when
Position
is -5000.
Note: As long as MC_MoveAbsolute instruction which is being executed is aborted, its uncompleted
distance will be discarded and the new instruction will be executed.
Direction
Direction
is valid when the axis is a rotary axis and different motion directions of the axis are listed in the
following table based on different Direction value. (Modulo: 360)
Pos it ion
Time
5000
10000
0
Position= 5000
Position= -5000
Pos ition
10000
0
Time
St ar t po si ti on
Po si tion >0
Positi on<0
St art pos it ion
Targ et pos it i on
Target p os it ion
-5000
11-55
Summary of Contents for DVP15MC11T
Page 9: ...Memo viii...
Page 15: ...DVP15MC11T Operation Manual _2 MEMO 2 4...
Page 71: ...DVP15MC11T Operation Manual _7 Memo 7 10...
Page 81: ...DVP15MC11T Operation Manual _8 Timing Chart F_TRG_CLK F_TRG_Q 8 10...
Page 158: ...Chapter 8 Logic Instructions 8_ The program 1 ASIN EN ENO In Out ASIN_EN ASIN_In Out1 8 87...
Page 249: ...DVP15MC11T Operation Manual _8 8 178...
Page 285: ...DVP15MC11T Operation Manual _8 Memo 8 214...
Page 323: ...DVP15MC11T Operation Manual 10 MEMO 10 34...
Page 549: ...DVP15MC11T Operation Manual A MEMO A 16...