NOTE: Use the
start physicalDiskChannel faultDiagnostics
command and the
save
physicalDiskChannel faultDiagnostics
command with the
stop physicalDiskChannel
faultDiagnostics
command. These commands are needed to start the diagnostic test and save diagnostic
test results to a file. You can also stop the
start physicalDiskChannel faultDiagnostics
command at any time by pressing <Ctrl><C>.
Stop Snapshot
This command stops a copy-on-write operation.
Syntax
stop snapshot (virtualDisk [
virtualDiskName
] |
virtualDisks [
virtualDiskName1... virtualDiskNameN
])
Parameter
Parameter
Description
virtualDisk or virtualDisks
Name of the virtual disk for which to start the formatting.
You must put brackets ([ ]) around the virtual disk name. If
the virtual disk name has special characters, you must
also put quotation marks (" ") around the virtual disk name.
Stop Storage Array Blink
This command turns off the indicator lights on the storage array that were turned on by the
start storageArray
blink
command.
Syntax
stop storageArray blink
Parameters
None.
Stop Storage Array iSCSI Session
This command forces the termination of an iSCSI session
Syntax
stop storageArray iscsiSession [
sessionNumber
]
Parameter
Parameter
Description
sessioNumber
The identifier number of the iSCSI session. Enclose the
identifier number of the iSCSI session in square brackets
([ ]).
Stop Storage Array Physical Disk Firmware Download
This command stops a firmware download to the physical disks in a storage array that was started with the
download
storageArray physicalDiskFirmware
command. This command does not stop a firmware download that is
217
Summary of Contents for PowerVault MD3060e Series
Page 1: ...Dell PowerVault Modular Disk Storage Arrays CLI Guide ...
Page 22: ...22 ...
Page 32: ...32 ...
Page 56: ...56 ...
Page 66: ...66 ...
Page 88: ...88 ...
Page 220: ...NOTE If your pass phrase does not meet these criteria you receive an error message 220 ...
Page 224: ...224 ...