Options for the
Ethernet Port
Parameter
enableIPv6Priority=(TRUE | FALSE) |
IPv4ConfigurationMethod=(static | dhcp) |
IPv6ConfigurationMethod=(static | auto) |
IPv4GatewayIP=(TRUE | FALSE) |
IPv6Priority=[0-7] |
IPv4SubnetMask=(0-255).(0-255).(0-255).(0-255)|
IPv4VlanId=[1-4094] |
IPv6VlanId=[1-4094] |
maxFramePayload=[frameSize] |
tcpListeningPort=[3260, 49152-65536] |
portSpeed=[(autoNegotiate | 1 | 10)]
Additional Information
When you use this command, you can specify one or more of the parameters. You do not need to use all of the
parameters. Setting the
availability
parameter to
serviceMode
causes the alternate RAID controller module to
take ownership of all of the virtual disks. The specified RAID controller module no longer has any virtual disks and
refuses to take ownership of any more virtual disks. Service mode is persistent across reset cycles and power cycles
until the availability parameter is set to online.
Use the
show controller NVSRAM
command to show the NVSRAM information. When the duplexMode option is
set to
TRUE
, the selected Ethernet port is set to full duplex. The default value is half duplex (the
duplexMode
parameter is set to
FALSE
).
To make sure that the IPv4 settings or the IPv6 settings are applied, you must set these
iscsiHostPort
options:
•
enableIPV4=TRUE
•
enableIPV6=TRUE
The IPv6 address space is 128 bits. It is represented by eight 16-bit hexadecimal blocks separated by colons. The
maxFramePayload option is shared between IPv4 and IPv6. The payload portion of a standard Ethernet frame is set to
1500, and a jumbo Ethernet frame is set to 9000. When using jumbo frames, all of the devices that are in the network path
should be capable of handling the larger frame size.
The portSpeed option is expressed as megabits per second (Mb/s). The following values are the default values for the
iscsiHostOptions
:
•
The IPv6HopLimit option is 64.
•
The IPv6NdReachableTime option is 30000 milliseconds.
•
The IPv6NdRetransmitTime option is 1000 milliseconds.
•
The IPv6NdTimeOut option is 30000 milliseconds.
•
The tcpListeningPort parameter is 3260.
Values for the portSpeed option of the
iscsiHostPort
parameter are in megabits per second (Mb/s).
Set Remote Replication
NOTE: This command valid only with Fibre Channel storage arrays.
This command defines the properties for a remote replication pair.
Syntax
set remoteReplication (localVirtualDisk
[
virtualDiskName
] |
localVirtualDisks [
virtualDiskName1 ...
177
Summary of Contents for PowerVault MD3060e Series
Page 1: ...Dell PowerVault Modular Disk Storage Arrays CLI Guide ...
Page 22: ...22 ...
Page 32: ...32 ...
Page 56: ...56 ...
Page 66: ...66 ...
Page 88: ...88 ...
Page 220: ...NOTE If your pass phrase does not meet these criteria you receive an error message 220 ...
Page 224: ...224 ...