7.5.6 EV GetWaferScoreAs100
EV GetWaferScoreAs100(<WafID>)
Returns the state of the optional scoring setting for character positions fielded as dashes
(-), dots (.) and spaces. This setting is only available for ‘Chars, SEMI’, ‘Chars, IBM’ and
‘Chars, Triple’ Marks.
Inputs
: WafID
Outputs
: Status Code, # of bytes, State
Sample Input and Output
EV GETWAFERSCOREAS100(A4)
1
18
<Float>0</Float>
7.5.7 EV GetWaferSummary
EV GetWaferSummary(<WafID>)
Returns a summary of the results for the most recent read.
NOTE
A ConfigLog will be returned for all Enabled Configs.
Inputs
: WafID
Outputs
: Status Code, # of bytes, BestConfig, Passed, String, Score, Row (Region), Col
(Region), High (Region), Wide (Region), NumPassed, NumFailed, AvgScore, ReadLog,
Passed (ConfigLog), String (ConfigLog), Score (ConfigLog), TryLog (ConfigLog),
TuneLog (ConfigLog), NumPassed (ConfigLog), NumFailed (ConfigLog),
NumTunedPassed (ConfigLog), NumTuneFailed (ConfigLog), AvgScore (ConfigLog)
Summary of Contents for In-Sight 1721
Page 1: ...IN SIGHT 1700 SERIES WAFER READER USER MANUAL...
Page 2: ......
Page 8: ...In Sight 1700 Series Wafer Reader vi...
Page 58: ...Section 4 Managing Job Files In Sight 1700 Series Wafer Reader 48...
Page 130: ...Section 8 Specifications In Sight 1700 Series Wafer Reader 120...
Page 136: ...Updating the Wafer Reader s Firmware In Sight 1700 Series Wafer Reader 126...
Page 140: ...Configuring Microsoft Windows Network Settings In Sight 1700 Series Wafer Reader 130...
Page 154: ...In Sight 1700 Wafer Reader Mount Conversion In Sight 1700 Series Wafer Reader 144...
Page 156: ...In Sight 1700 Series Wafer Reader www cognex com products InSight default asp Rev 16 May 2006...