Section 7: Native Mode Commands
In-Sight
®
1700 Series Wafer Reader
74
7.4 Evaluate Extended Native Mode Commands
(Actions)
The following commands are used in conjunction with the Evaluate (EV) extended Native
Mode command to remotely control a wafer reader from user-designed software. Each
command returns a Status Code, the number of characters (in bytes, including Carriage
Returns and Line Feeds) in the output that follows, and the results in XML format.
Syntax
: EV [command]
The status codes for all Evaluate commands are:
STATUS CODE
DESCRIPTION
1
The command was executed successfully.
0 Unrecognized
command.
-2
The command could not be executed.
7.4.1 EV AcquireConfig
EV AcquireConfig(<WafID>,<Config>)
Acquires an image using the light settings in the specified Config. This command does
not read.
Inputs
: WafID, Config
Output
: Status Code, # of bytes
Sample Input and Output
EV ACQUIRECONFIG(A4,0)
1
0
7.4.2 EV CopyConfig
EV CopyConfig
(<
WafID
>,<
TargetConfig
>,<
SourceConfig
>)
Copies all settings and read results from the source Config to the target Config.
Inputs
: WafID, TargetConfig, SourceConfig
Output
: Status Code, # of bytes
Sample Input and Output
EV COPYCONFIG(A4,0,1)
1
0
Summary of Contents for In-Sight 1721
Page 1: ...IN SIGHT 1700 SERIES WAFER READER USER MANUAL...
Page 2: ......
Page 8: ...In Sight 1700 Series Wafer Reader vi...
Page 58: ...Section 4 Managing Job Files In Sight 1700 Series Wafer Reader 48...
Page 130: ...Section 8 Specifications In Sight 1700 Series Wafer Reader 120...
Page 136: ...Updating the Wafer Reader s Firmware In Sight 1700 Series Wafer Reader 126...
Page 140: ...Configuring Microsoft Windows Network Settings In Sight 1700 Series Wafer Reader 130...
Page 154: ...In Sight 1700 Wafer Reader Mount Conversion In Sight 1700 Series Wafer Reader 144...
Page 156: ...In Sight 1700 Series Wafer Reader www cognex com products InSight default asp Rev 16 May 2006...