1721/1722 Wafer Reader Installation Options
In-Sight
®
1700 Series Wafer Reader
134
The working distance is adjustable, with a factory-set option of 50.0mm when vertically mounted.
The useable working distance range is 1 to 80.0mm for the wafer reader in the vertical position.
NOTE
The Image Orientation may need to be adjusted, depending on the configuration of the wafer
reader and the mirror attachment installation.
Figure D-3: Working Distances in Horizontal and Vertical Mounting Configurations
NOTE
The wafer reader can be mounted face-up or face-down in both horizontal mirror mounting
configurations.