Section 3: Configuring a Wafer ID Application
In-Sight
®
1700 Series Wafer Reader
32
3.5.14 Region
The
Region
defines the area in which the wafer mark is expected to appear in the FOV.
The mark must be sufficiently illuminated and entirely contained within the Region or the
read will fail. Generally, the mark may be rotated as much as
±
5 degrees within the
horizontal axis of the region without a significant decrease in readability. The image
coordinates and the size of the region (row, column, height, width) are displayed below
the box. If a rotation or curve is set for the Region, the Theta (rotation) and Phi
(curvature) are also displayed.
To set the Region:
1
Click the
Edit Region
button. The image area will expand, and the interactive region
box will appear (Figure 3-6).
Figure 3-6: Editing the Region
2
Adjust the region as necessary to encompass the entire mark.
To move the region, position the
cursor anywhere inside the box, then click
and hold the left mouse button while dragging. To move the region one pixel at a
time, use the arrow keys on the keyboard.
To resize the region, position the cursor over an edge or corner of the region,
then click and hold the left mouse button while dragging. To resize the region one
pixel at a time, use Shift-arrow keys.
Summary of Contents for In-Sight 1721
Page 1: ...IN SIGHT 1700 SERIES WAFER READER USER MANUAL...
Page 2: ......
Page 8: ...In Sight 1700 Series Wafer Reader vi...
Page 58: ...Section 4 Managing Job Files In Sight 1700 Series Wafer Reader 48...
Page 130: ...Section 8 Specifications In Sight 1700 Series Wafer Reader 120...
Page 136: ...Updating the Wafer Reader s Firmware In Sight 1700 Series Wafer Reader 126...
Page 140: ...Configuring Microsoft Windows Network Settings In Sight 1700 Series Wafer Reader 130...
Page 154: ...In Sight 1700 Wafer Reader Mount Conversion In Sight 1700 Series Wafer Reader 144...
Page 156: ...In Sight 1700 Series Wafer Reader www cognex com products InSight default asp Rev 16 May 2006...