In-Sight
®
1700 Series Wafer Reader
Section 7: Native Mode Commands
65
7.1.2 Send Message
SM"
string
"[
Event
]
Allows In-Sight protocol commands (see Section 3.6.2: Input/Output) to be sent over a
Native Mode connection to a wafer reader as a text string, and optionally, triggers a
spreadsheet Event.
Inputs
: String, Event (Optional).
The Event codes are:
EVENT CODE
DESCRIPTION
(0 to 7)
Specifies a soft trigger (Soft 0, Soft 1, ... Soft 7).
8
Acquire an image and update the spreadsheet. This option requires the AcquireImage
function’s Trigger argument to be External or Manual.
NOTE
The string must be set off with quotations marks.
Output
: Status Code, Read Result.
The status codes are:
STATUS CODE
DESCRIPTION
1
The command was executed successfully.
0 Unrecognized
command.
-2
The command could not be executed.
NOTE
The outputs for the read result depend on which of the Output String, Output Score, and Output
Passed checkboxes are selected from the Options tab (see Section 3.6: Setting Options)
Sample Inputs and Outputs
SM"READ"0
1
[UH587IX1CGC3,398.000,1.000]
SM"TUNE(0)"0
1
[UH587IX1CGC3,391.000,1.000]
Summary of Contents for In-Sight 1721
Page 1: ...IN SIGHT 1700 SERIES WAFER READER USER MANUAL...
Page 2: ......
Page 8: ...In Sight 1700 Series Wafer Reader vi...
Page 58: ...Section 4 Managing Job Files In Sight 1700 Series Wafer Reader 48...
Page 130: ...Section 8 Specifications In Sight 1700 Series Wafer Reader 120...
Page 136: ...Updating the Wafer Reader s Firmware In Sight 1700 Series Wafer Reader 126...
Page 140: ...Configuring Microsoft Windows Network Settings In Sight 1700 Series Wafer Reader 130...
Page 154: ...In Sight 1700 Wafer Reader Mount Conversion In Sight 1700 Series Wafer Reader 144...
Page 156: ...In Sight 1700 Series Wafer Reader www cognex com products InSight default asp Rev 16 May 2006...