Section 7: Native Mode Commands
In-Sight
®
1700 Series Wafer Reader
98
7.6.18 EV SetConfigRegion
EV SetConfigRegion(<WafID>,<Config>,<Row>,<Col>,<High>,<Wide>)
Sets the region where the wafer mark is expected to appear in the field of view for the
specified Config.
Inputs
: WafID, Config, Row, Col, High, Wide
Outputs
: Status Code, # of bytes
Sample Input and Output
EV SETCONFIGREGION(A4,0,150,60,100,500)
1
0
7.6.19 EV SetConfigRetry
EV SetConfigRetry(<WafID>,<Config>,<Retry>)
Specifies how the Config will be used during the retry sequence at runtime.
Inputs
:
WafID, Config, Retry
Outputs
: Status Code, # of bytes
Sample Input and Output
EV SETCONFIGRETRY(A4,0,1)
1
0
7.6.20 EV SetConfigThresh
EV SetConfigThresh(<WafID>,<Config>,<Thresh>)
Specifies the minimum response threshold for each individual character score. Each
individual character score must be greater than the Character Threshold or the read will
fail.
Inputs
:
WafID, Config, Thresh
Outputs
: Status Code, # of bytes
Sample Input and Output
EV SETCONFIGTHRESH(A4,0,50)
1
0
Summary of Contents for In-Sight 1721
Page 1: ...IN SIGHT 1700 SERIES WAFER READER USER MANUAL...
Page 2: ......
Page 8: ...In Sight 1700 Series Wafer Reader vi...
Page 58: ...Section 4 Managing Job Files In Sight 1700 Series Wafer Reader 48...
Page 130: ...Section 8 Specifications In Sight 1700 Series Wafer Reader 120...
Page 136: ...Updating the Wafer Reader s Firmware In Sight 1700 Series Wafer Reader 126...
Page 140: ...Configuring Microsoft Windows Network Settings In Sight 1700 Series Wafer Reader 130...
Page 154: ...In Sight 1700 Wafer Reader Mount Conversion In Sight 1700 Series Wafer Reader 144...
Page 156: ...In Sight 1700 Series Wafer Reader www cognex com products InSight default asp Rev 16 May 2006...