In-Sight
®
1700 Series Wafer Reader
Section 3: Configuring a Wafer ID Application
NOTES
■
Speed is the default Optimization setting that is used for compatibility with all previous versions of
the In-Sight wafer reader.
■
The read score may vary depending on the Optimization setting; verify that the Accept and Char
Threshold settings correspond to the selected Optimization setting.
BC, Compress Advanced Dialog
When ‘BC, BC 412’ or ‘BC, IBM 412’ is the selected Mark, the Advanced dialog can be
accessed from the Advanced button (see Figure 3-5).
Figure 3-5: BC, Compress Advanced Dialog
The
Compression
drop-down list specifies options for decoding compressed barcodes,
including Base 35 compression, as well as a selection for decoding a barcode with no
compression.
When one of the Compressed options (Compressed 1 to Compressed 8) is selected,
Report
settings are also available. If
Hyphen
is enabled, the last two digits of the
barcode string are separated by a hyphen. If
Three Digit
is enabled, the digits that are
encoded for the wafer lot number are replaced by a three-digit number; zeros (0) are
used as place-holders if the lot number is less than three digits. For example, if the
encoded lot number is “12”, the lot number would be reported as “012”. Report settings
are ignored if ‘None’ is the selected Compression.
NOTE
For specific information on the customized decoding options, please contact your Cognex Sales
Engineer.
3.5.5 Checksum
The
Checksum
setting selects the method by which the read result from a character
string will be validated to ensure reliability, and establishes the scoring basis for
determining the pass/fail status of the read.
NOTE
The Checksum setting is enabled and used only when ‘Chars, SEMI’, or ‘Chars, Triple’ is the
selected Mark. When any other Mark is selected, the Checksum setting is ignored.
25
Summary of Contents for In-Sight 1721
Page 1: ...IN SIGHT 1700 SERIES WAFER READER USER MANUAL...
Page 2: ......
Page 8: ...In Sight 1700 Series Wafer Reader vi...
Page 58: ...Section 4 Managing Job Files In Sight 1700 Series Wafer Reader 48...
Page 130: ...Section 8 Specifications In Sight 1700 Series Wafer Reader 120...
Page 136: ...Updating the Wafer Reader s Firmware In Sight 1700 Series Wafer Reader 126...
Page 140: ...Configuring Microsoft Windows Network Settings In Sight 1700 Series Wafer Reader 130...
Page 154: ...In Sight 1700 Wafer Reader Mount Conversion In Sight 1700 Series Wafer Reader 144...
Page 156: ...In Sight 1700 Series Wafer Reader www cognex com products InSight default asp Rev 16 May 2006...