Section 7: Native Mode Commands
In-Sight
®
1700 Series Wafer Reader
66
7.1.3 Set Online
SO[
int
]
Sets the In-Sight wafer reader into Online or Offline mode.
NOTE
This command cannot set the In-Sight wafer reader Online if it was previously set Offline manually
through the user interface, or by a discrete input signal.
Inputs
:
0
to set In-Sight Offline, and
1
to set In-Sight Online.
Output
: Status Code.
The status codes are:
STATUS CODE
DESCRIPTION
1
The command was executed successfully.
0 Unrecognized
command.
-1
The value given for
int
is either out of range, or is not a valid integer.
-5
The communications flag was successful but the wafer reader did not go Online because the
wafer reader is set Offline manually through the user interface or the Discrete I/O setting is
off.
Sample Input and Output
SO1
1