1-71
Cisco ASR 901 Aggregation Services Router Command Reference Guide
OL-26031-07
Chapter 1 CLI Command Reference
network-clock external hold-off
network-clock external hold-off
To override hold-off timer value for external interface, use the
network-clock external hold-off
command. Use the
no
form of the command to disable the configuration.
network-clock external
<slot/card/port>
hold-off {
0
|
<50-10000>
}
no network-clock external
<slot/card/port>
hold-off {
0
|
<50-10000>
}
Syntax Description
Command Modes
Global configuration
Command History
Usage Guidelines
The ASR 901 router displays a warning message for values above 1800 ms, as waiting longer causes the
clock to go into the holdover mode.
Examples
This example specifies the hold-off timer value for the external interface.
Router(config)#
network-clock external 3/1/1 hold-off 300
Related Commands
slot/port/card
Specifies the slot, card, or port of the interface used for timing.
hold-off
Specifies the hold-off timer value.
Release
Modification
15.1(2)SNG
Support for this command was introduced on the Cisco ASR 901 router.
Command
Description
network-clock
hold-off
Configures general hold-off timer in milliseconds.