King Edge Vac
Preventive Maintenance
4-5
Check and Clean Inverters
Check and clean the inverters and their cooling
fins (Figure 4-4) weekly with a vacuum cleaner.
Failure to do so may void your warranty.
Required Tools
vacuum cleaner
Perform only when the unit is OFF
with power disconnected.
Turn power OFF at the main disconnect
switch.
Open both the right and left endframe
doors.
CAUTION
Failure to clean the inverter
and its cooling fins could
void the warranty.
Never use compressed air
on or around electronic
components. Doing so may
damage them.
Check and clean all inverters and their
cooling fins with a vacuum cleaner.
Close and secure both endframe doors.
1.
2.
3.
4.
Check For String Accumulation
Check for accumulated string and lint on the
drive shaft rollers and bearings.
Perform only when the unit is OFF
with power disconnected.
Check Rodless Air Cylinder
Bearings
Perform only when the unit is OFF
with power disconnected.
Make sure that the transfer clamp carriage is
moving smoothly along the length of the rodless
air cylinder, without any lateral movement or
play (Figure 4-5).
To ensure proper operation of the transfer
clamp assembly and maximize the life of the
cylinder, the bearings must be replaced at least
every six months. Sooner if needed.
If metal is visible in the cylinder bearings
groove, the bearings will have to be changed more
often. If the groove gets too deep, the cylinder
will have to be replaced.
For more information within this chapter,
refer to the
Semi-Annual PM
section,
Replace
Rodless Air Cylinder Bearings
procedure.
Figure 4-5 There should be no lateral movement
on the transfer clamp assembly.
Figure 4-4: Inverters in the endframe panels.
Right endframe inverters
Left endframe inverters
TOC
INDEX
Summary of Contents for King Edge VAc
Page 12: ......
Page 40: ......
Page 54: ......
Page 78: ......
Page 250: ...3038 015e King Edge VAC PL 32 This page intentionally left blank TOC INDEX PL TOC...
Page 262: ...SC 2 460V Motor Circuit SC TOC TOC INDEX...
Page 264: ...SC 4 208 230V Motor Circuit SC TOC TOC INDEX...
Page 266: ...SC 6 Control Power Communications SC TOC TOC INDEX...
Page 268: ...SC 8 Controller Inputs SC TOC TOC INDEX...
Page 270: ...SC 10 Control Outputs SC TOC TOC INDEX...
Page 273: ...King Edge Vac 3210 437b SC 13 This page intentionally left blank SC TOC TOC INDEX...
Page 274: ...SC 14 Prefeeder Control Circuit SC TOC TOC INDEX...
Page 276: ...3210 437b King Edge Vac SC 16 This page intentionally left blank SC TOC TOC INDEX...
Page 277: ...SC 17 24 VAC Control Circuit SC TOC TOC INDEX...
Page 278: ...SC 18 Interlock Circuit system E stop SC TOC TOC INDEX...
Page 279: ...SC 19 Pneumatic Diagram SC TOC TOC INDEX...
Page 280: ...SC 20 Prefeeder Electrical Panel SC TOC TOC INDEX...
Page 282: ...SC 22 Disconnect Panel SC TOC TOC INDEX...
Page 284: ...SC 24 Main Eletrical Panel SC TOC TOC INDEX...
Page 285: ......
Page 286: ......
Page 287: ......
Page 288: ......
Page 290: ......
Page 292: ......
Page 302: ......