Preventive Maintenance
King Edge Vac
4-20
Replace Rodless Air Cylinder
Bearings
Required Tools
part #0208-491, metric Allen wrench,
small slotted screwdriver, Loctite
®
243
thread lock
Perform only when the unit is OFF
with power disconnected.
NOTE:
This procedure requires
Repair Kit 11” Rodless Air Cylinder
(part #0208-491).
Turn power OFF at the main disconnect
switch.
Turn OFF the compressed air supply to
the unit.
Make sure the compressed air system is
depressurized.
Carefully measure the distance from the
back edge of the rodless center mounting
bracket to the back of the cylinder itself
(Figure 4-28). Write the information
down. This is important to ensure proper
re-installation.
Remove the four bolts which secure the
transfer clamp assembly to the rodless air
cylinder (Figure 4-29).
Carefully place the assembly, with its at-
tached air hoses on the air foil.
Remove the air hoses connected to the
rodless air cylinder (Figure 4-30, A).
Remove the 8 screws, nuts and washers
(four on the front end, four on the back end
Figure 4-30, B) which secure the rodless
air cylinder to its bracket.
Remove the rodless air cylinder from the
machine and place on a work table.
1.
2.
3.
4.
5.
6.
7.
8.
9.
Figure 4-29: Four bolts secure the transfer clamp
assembly to the rodless air cylinder.
Figure 4-30: Remove the rodless air cylinder from
its mounting bracket.
A
A
Figure 4-28: Carefully measure the distance from
the end of the bracket to the end of the
air cylinder.
TOC
INDEX
Summary of Contents for King Edge VAc
Page 12: ......
Page 40: ......
Page 54: ......
Page 78: ......
Page 250: ...3038 015e King Edge VAC PL 32 This page intentionally left blank TOC INDEX PL TOC...
Page 262: ...SC 2 460V Motor Circuit SC TOC TOC INDEX...
Page 264: ...SC 4 208 230V Motor Circuit SC TOC TOC INDEX...
Page 266: ...SC 6 Control Power Communications SC TOC TOC INDEX...
Page 268: ...SC 8 Controller Inputs SC TOC TOC INDEX...
Page 270: ...SC 10 Control Outputs SC TOC TOC INDEX...
Page 273: ...King Edge Vac 3210 437b SC 13 This page intentionally left blank SC TOC TOC INDEX...
Page 274: ...SC 14 Prefeeder Control Circuit SC TOC TOC INDEX...
Page 276: ...3210 437b King Edge Vac SC 16 This page intentionally left blank SC TOC TOC INDEX...
Page 277: ...SC 17 24 VAC Control Circuit SC TOC TOC INDEX...
Page 278: ...SC 18 Interlock Circuit system E stop SC TOC TOC INDEX...
Page 279: ...SC 19 Pneumatic Diagram SC TOC TOC INDEX...
Page 280: ...SC 20 Prefeeder Electrical Panel SC TOC TOC INDEX...
Page 282: ...SC 22 Disconnect Panel SC TOC TOC INDEX...
Page 284: ...SC 24 Main Eletrical Panel SC TOC TOC INDEX...
Page 285: ......
Page 286: ......
Page 287: ......
Page 288: ......
Page 290: ......
Page 292: ......
Page 302: ......