King Edge Vac
Troubleshooting
6-25
WARNING
Only trained personnel with experience
in electrical or mechanical repair should
troubleshoot and repair the unit.
Troubleshooting
WARNING
Read the
REPAIR
chapter and make
sure that the power is disconnected
before doing any repairs.
ISSUE
POSSIBLE CAUSE
SOLUTION
Leading Edge of Flatwork
Folded Over
1. The corners are too long.
Check sensor alignment in front of
clutch rolls. Refer to the
REPAIR
chap-
ter,
Sensors
section,
Roll Photosen-
sor Alignment
procedure.
Adjust CORNER STOP DLY. Refer to
the
CHI PANEL OPERATION
bulletin,
Adjustment
section,
Inlet Adjust-
ments (INL)
procedure.
•
•
2. Mechanical problem with
the spread clamp or its air
cylinder.
Check/adjust. Refer to the
REPAIR
chapter,
Spread Section
section,
Spreader Clamp Mechanical Adjust-
ment
procedure.
•
3. CORNER STOP DELAY
settings need adjustment.
Adjust. Refer to the
CHI PANEL
OPERATION
bulletin,
Adjustment
section,
Inlet Section Adjustments
procedure.
•
4. LET setting is too long.
LET controls time between air blast
and spread clamp/finger release.
Check, shorten if necessary. Refer to
the
CHI PANEL OPERATION
bulletin,
Adjustment
section,
CHI Adjust-
ments
procedure.
•
Leading Edge of Flatwork
Misaligned
(continued on next page)
1. Mechanical problem with
the spread clamp or its air
cylinder.
Check/adjust. Refer to the
REPAIR
chapter,
Spread Section
section,
Spreader Clamp Mechanical Adjust-
ment
procedure.
•
2. Corner sizes are not even.
Check the corner sensors. Refer to
the
REPAIR
chapter,
Sensors
sec-
tion,
Corner Photosensor Alignment
procedure.
•
3. Air bars out of alignment.
Adjust. Refer to the
REPAIR
chapter,
Compressed Air System
section,
Air
Bar Alignment
procedure.
•
4. Gaps between lower
spreader belts are not
even left side to right side,
causing flatwork to pull to
one side.
Adjust. Refer to the
REPAIR
chap-
ter,
Spread Section
section,
Lower
Spreader Belt Gap Adjustment
procedure.
•
5. LET setting is too long.
LET controls time between air blast
and spread clamp/finger release.
Check, shorten if necessary. Refer to
the
CHI PANEL OPERATION
bulletin,
Adjustment
section,
CHI Adjust-
ments
procedure.
•
TOC
INDEX
Summary of Contents for King Edge VAc
Page 12: ......
Page 40: ......
Page 54: ......
Page 78: ......
Page 250: ...3038 015e King Edge VAC PL 32 This page intentionally left blank TOC INDEX PL TOC...
Page 262: ...SC 2 460V Motor Circuit SC TOC TOC INDEX...
Page 264: ...SC 4 208 230V Motor Circuit SC TOC TOC INDEX...
Page 266: ...SC 6 Control Power Communications SC TOC TOC INDEX...
Page 268: ...SC 8 Controller Inputs SC TOC TOC INDEX...
Page 270: ...SC 10 Control Outputs SC TOC TOC INDEX...
Page 273: ...King Edge Vac 3210 437b SC 13 This page intentionally left blank SC TOC TOC INDEX...
Page 274: ...SC 14 Prefeeder Control Circuit SC TOC TOC INDEX...
Page 276: ...3210 437b King Edge Vac SC 16 This page intentionally left blank SC TOC TOC INDEX...
Page 277: ...SC 17 24 VAC Control Circuit SC TOC TOC INDEX...
Page 278: ...SC 18 Interlock Circuit system E stop SC TOC TOC INDEX...
Page 279: ...SC 19 Pneumatic Diagram SC TOC TOC INDEX...
Page 280: ...SC 20 Prefeeder Electrical Panel SC TOC TOC INDEX...
Page 282: ...SC 22 Disconnect Panel SC TOC TOC INDEX...
Page 284: ...SC 24 Main Eletrical Panel SC TOC TOC INDEX...
Page 285: ......
Page 286: ......
Page 287: ......
Page 288: ......
Page 290: ......
Page 292: ......
Page 302: ......