Troubleshooting
King Edge Vac
6-28
WARNING
Only trained personnel with experience
in electrical or mechanical repair should
troubleshoot and repair the unit.
Troubleshooting
WARNING
Read the
REPAIR
chapter and make
sure that the power is disconnected
before doing any repairs.
6.10 CHI Panel
ISSUE
CAUSE
SOLUTION
CHI Panel is Not Functioning
No error message
1. 2-wire power cable from
MPC1 for power to the
CHI Panel is not con-
nected.
Reconnect; replace if necessary.
•
CHI Panel is Not Functioning
Message reads:
COMMUNICATION ERROR/
FAULTY CODE RETURNED
1. 4-wire communications
cable from the CHI Panel
to MPC1 is loose.
Check and repair connection at both
ends.
•
2. Communication cable is
attached backward.
Turn the connector over.
•
3. Power supply/AC detect
board PSC1 is not sup-
pling power to the CHI
Panel.
Check. Replace defective board as
necessary.
•
4. MPC1 Machine Controller
circuit board is bad.
Replace.
•
CHI Panel is Not Functioning
Message reads:
COMMUNICATION ERROR/
NO RESPONSE FROM CON-
TROL
1. 4-wire communications
cable from the CHI Panel
to MPC1 is loose.
Check and repair connection at both
ends.
•
2. Communication cable has
broken wire.
Repair or replace.
•
3. MPC1 Machine Controller
circuit board is bad.
Replace.
•
CHI Panel Doesn’t Change
Programs
1. Ironer is not started.
Start.
•
2. Folder not started.
Start folder unit.
•
3. CHI Panel is faulty.
Check and replace.
•
4. MPC1 Machine Controller
circuit board is bad.
Replace.
•
Parameter Error Message
Message reads:
MEMORY ERROR/
PARAMETERS WILL DEFAULT
1. CHI Panel component is
missing or bad.
CHI Panel contains a static memory
with the laundry’s specific program-
ming selections. Contact an authorized
service outlet for instructions.
•
Parameter Error Message
Message reads:
MEMORY INITIALIZED/
ADJUST ALL PARAMETERS
1. After replacement, the CHI
Panel chip only recognizes
factory defaults.
All programs need to be reset. Refer
to the
CHI PANEL OPERATION
bul-
letin,
Programming
and
Adjustment
sections.
•
TOC
INDEX
Summary of Contents for King Edge VAc
Page 12: ......
Page 40: ......
Page 54: ......
Page 78: ......
Page 250: ...3038 015e King Edge VAC PL 32 This page intentionally left blank TOC INDEX PL TOC...
Page 262: ...SC 2 460V Motor Circuit SC TOC TOC INDEX...
Page 264: ...SC 4 208 230V Motor Circuit SC TOC TOC INDEX...
Page 266: ...SC 6 Control Power Communications SC TOC TOC INDEX...
Page 268: ...SC 8 Controller Inputs SC TOC TOC INDEX...
Page 270: ...SC 10 Control Outputs SC TOC TOC INDEX...
Page 273: ...King Edge Vac 3210 437b SC 13 This page intentionally left blank SC TOC TOC INDEX...
Page 274: ...SC 14 Prefeeder Control Circuit SC TOC TOC INDEX...
Page 276: ...3210 437b King Edge Vac SC 16 This page intentionally left blank SC TOC TOC INDEX...
Page 277: ...SC 17 24 VAC Control Circuit SC TOC TOC INDEX...
Page 278: ...SC 18 Interlock Circuit system E stop SC TOC TOC INDEX...
Page 279: ...SC 19 Pneumatic Diagram SC TOC TOC INDEX...
Page 280: ...SC 20 Prefeeder Electrical Panel SC TOC TOC INDEX...
Page 282: ...SC 22 Disconnect Panel SC TOC TOC INDEX...
Page 284: ...SC 24 Main Eletrical Panel SC TOC TOC INDEX...
Page 285: ......
Page 286: ......
Page 287: ......
Page 288: ......
Page 290: ......
Page 292: ......
Page 302: ......