9
9
9-3
9-3
Installation■>■Points■to■Note■Before■Installation
Installation■>■Points■to■Note■Before■Installation
•■ Duplex■Color■Image■Reader■Unit-B1+Inner■Finisher-A1+and■Paper■Deck■Unit-B1
19 3/4” (500 mm) or more
19 3/4”
(500 mm)
or more
19 3/4”
(500 mm)
or more
46 5/8” (1,184 mm)
4” (100 mm) or more
50 5/8” (1,284 mm)
58 1/2” (1,487 mm)
•■ Duplex■Color■Image■Reader■Unit-B1+External■2/3■Hole■Puncher-B1+Booklet■Finisher-
C1+Buffer■Pass■Unit-G1+■Paper■Deck■Unit-B1
19 3/4” (500 mm) or more
19 3/4”
(500 mm)
or more
19 3/4”
(500 mm)
or more
85 7/8” (
2,180
mm)
81 1/4” (
2,062 mm
)
46 5/8” (1,184 mm)
4” (100 mm) or more
4 5/8” (
118
mm)
7)■Be■sure■to■install■this■equipment■in■a■well-ventilated■place.■Do■not■place■this■equipment■
near■the■air■vent■in■the■room.
F-9-4
F-9-5
Points■to■Note■Before■Installation
Take■note■of■the■following■points■when■installing■this■equipment.
1)■Moving■this■equipment■from■a■low-temperature■place■to■a■warm■plate■can■generate■
condensation,■resulting■in■image■fault.■Thus,■when■unpacking■this■equipment,■leave■it■for■2■
hours■or■more■so■that■the■equipment■becomes■comfortable■with■the■room■temperature.
(Condensation:■formation■of■liquid■drops■from■water■vapor■on■metal■surface,■and■usually■
occurs■when■bringing■a■metal■object■from■a■low-temperature■place■to■a■warm■place■due■to■
rapidly-cooled■surrounding■moisture■vapor.)
2)■The■host■machine■weighs■maximum■175kg.■It■is■recommended■to■lift■it■with■4■people■or■
more.■However,■if■there■is■a■standard■to■handle■a■heavy■load■in■each■sales■company,■follow■
it■for■operation.■
Also,■make■sure■to■lift■the■machine■with■keeping■it■level■at■operation.