8
8
8-216
8-216
Service Mode > COPIER > OPTION > USER
Service Mode > COPIER > OPTION > USER
COPIER > OPTION > USER
IFAX-OF
IFAX send prohibition to entered address
Lv.1 Details
To set to prohibit the IFAX transmission to entered address.
I-Fax transmission is not available by entering the address because
of no “I-Fax” display on the transmission screen.
The addresses already registered in the Address Book can be
selected, but even if a job is sent, it is to be a transmission error. (End
code #762 is displayed.)
Use case
Upon user’s request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
- The addresses already registered in the Address Book can be
selected, but it is to be a transmission error. Therefore, be sure to
receive approval from the user in advance to delete the address. Set
the transmission prohibition after deleting the address.
- When #762 is displayed without executing the procedure above,
explain the user that it is different from the description in the User’s
Guide.
Display/adj/set range
0 to 1
0: Enabled, 1: Disabled
Default value
0
LDAP-DEF
Initial condtn set of LDAP server search
Lv.1 Details
To set initial condition for search target attribute that is specified at
the time of LDAP server Details search.
Use case
Upon user’s request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 6
0: Name, 1: E-mail, 2: FAX, 3: Organization, 4: Organization unit, 5:
No registration 1 (any setting), 6: No registration 2 (any setting)
Default value
0
Related service mode
COPIER > OPTION > USER > LDAP-SW
JA-DPI
Display of job archive record resolution
Lv.2 Details
To display the resolution of images for job archives recorded in jobs
other than FAX reception and I-Fax reception, etc.
Only display is available in service mode. The setting is available
only in the MEAP applications which support job archiving.
Use case
Upon user’s request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 3
0: No conversion, 1: 100 x 100 dpi, 2: 200 x 200 dpi, 3: 300 x 300 dpi
Default value
3
COPIER > OPTION > USER
JA-COMPR
Dspl job archive record compress ratio
Lv.2 Details
To display the compression ratio of images for job archives recorded
in jobs other than FAX reception and I-Fax reception, etc.
Only display is available in service mode. The setting is available
only in the MEAP applications which support job archiving.
Use case
Upon user’s request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 5
0: No conversion, 1: Compression ratio 1/4, 2: Compression ratio
1/8, 3: Compression ratio 1/16, 4: Compression ratio 1/32, 5:
Compression ratio 1/64
Default value
3
FREE-DSP
Display/hide of charge disable screen
Lv.2 Details
To set whether to display or hide the charge disable screen for
switching between charge and no charge.
The hardware switch for switching charge/no charge in the Coin
Manager enables the mode in which all the services are available
for free (store manager mode) by temporarily releasing the charging
system.
Even without the hardware switch, the mode can be switched with
the software switch when it is set to display the charge disable
screen in Settings/Registration.
Use case
When enabling all the services to be provided for free by temporarily
releasing the charging system
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: Hide, 1: Display
Default value
0
TNRB-SW
Display/hide of Toner Container counter
Lv.2 Details
To set whether to display the Toner Container counter on the Counter
Check screen.
Use case
When not showing the screen to users
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 2
0: Hide, 1: Display (Toner Container counter only), 2: Display (Toner
Container c ejection counter)
Default value