Service Mode > COPIER > OPTION > ENV-SET
Service Mode > COPIER > OPTION > ENV-SET
■
SOUND
COPIER > OPTION > SOUND
DRM-RTIM
Set Drum line prev sequence exe interval
Lv.2 Details
To set the time interval to rotate the Photosensitive Drum at standby
or sleep.
The Photosensitive Drum is rotated only for 300 msec at intervals to
prevent lines at the drum interval which occurs when the device is
not used for a long time.
As the value is incremented by 1, the interval is increased by 5
minutes.
Increase the value if the user does not mind line at the drum interval
or prefers to reduce the frequency of rotation.
Use case
When the user does not mind line at the drum interval which occurs
when the machine is not used for a long time or prefers to reduce the
frequency of rotation
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 12
0: Not executed
Unit
min
Default value
0
T-8-50
■
ENV-SET
COPIER > OPTION > ENV-SET
ENVP-INT
Temp, humid &Fix Film temp log get cycle
Lv.1 Details
To set the cycle to obtain log of the temperature and humidity inside
the machine and the surface temperature of the Fixing Film.
As the value is incremented by 1, the cycle is increased by 1 minute.
Obtained log can be displayed by selecting the following: COPIER >
DISPLAY > ENVRNT.
Use case
At problem analysis
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 480
Unit
min
Default value
60
Related service mode
COPIER> DISPLAY> ENVRNT
DRY-CISU
ON/OFF of condensation prevention mode
Lv.1 Details
To set ON/OFF of condensation prevention mode.
When droplets appear on the Scanner Unit in DADF mode due to
condensation and image failure or E302 occurs, set “1: ON”.
When 1 is selected, from the next startup, the paper back LED lights
for 30 seconds after completion of a job.
Use case
When droplets appear on the Scanner Unit due to condensation and
image failure or E302 occurs
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
This function works only on the one-pass model. It does not work on
the reverse model.
Display/adj/set range
0 to 1
0: OFF (Normal mode), 1: ON (Condensation prevention mode)
Default value
0
T-8-51