DLT-B-C2
ARCDAT scrn B C-density differ (1/2 SPD)
Lv.2 Details
To display the difference between the C-patch target value and the
current value of screen B in ARCDAT control at 1/2 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
DLT-B-K2
ARCDAT scrn B Bk-density differ(1/2 SPD)
Lv.2 Details
To display the difference between the Bk-patch target value and the
current value of screen B in ARCDAT control at 1/2 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
DLT-C-Y2
ARCDAT scrn C Y-density differ (1/2 SPD)
Lv.2 Details
To display the difference between the Y-patch target value and the
current value of screen C in ARCDAT control at 1/2 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
DLT-C-M2
ARCDAT scrn C M-density differ (1/2 SPD)
Lv.2 Details
To display the difference between the M-patch target value and the
current value of screen C in ARCDAT control at 1/2 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
DLT-C-C2
ARCDAT scrn C C-density differ (1/2 SPD)
Lv.2 Details
To display the difference between the C-patch target value and the
current value of screen C in ARCDAT control at 1/2 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
COPIER > DISPLAY > HT-C
DLT-C-K2
ARCDAT scrn C Bk-density differ(1/2 SPD)
Lv.2 Details
To display the difference between Bk-patch target value and the
current value of screen C in ARCDAT control at 1/2 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
SGL-A-Y2
ARCDAT scrnA Y-patch current VL(1/2 SPD)
Lv.2 Details
To display the current Y-patch value of screen A in ARCDAT control
at 1/2 speed.
When hue variation occurs and the value shown is not in the
tolerable range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
SGL-A-M2
ARCDAT scrnA M-patch current VL(1/2 SPD)
Lv.2 Details
To display the current M-patch value of screen A in ARCDAT control
at 1/2 speed.
When hue variation occurs and the value shown is not in the
tolerable range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
SGL-A-C2
ARCDAT scrnA C-patch current VL(1/2 SPD)
Lv.2 Details
To display the current C-patch value of screen A in ARCDAT control
at 1/2 speed.
When hue variation occurs and the value shown is not in the
tolerable range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
SGL-A-K2
ARCDAT scrnA Bk-patch current VL(1/2SPD)
Lv.2 Details
To display the current Bk-patch value of screen A in ARCDAT control
at 1/2 speed.
When hue variation occurs and the value shown is not in the
tolerable range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
SGL-B-Y2
ARCDAT scrnB Y-patch current VL(1/2 SPD)
Lv.2 Details
To display the current Y-patch value of screen B in ARCDAT control
at 1/2 speed.
When hue variation occurs and the value shown is not in the
tolerable range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Display/adj/set range