8
8
8-175
8-175
Service Mode > COPIER > OPTION > DSPLY-SW
Service Mode > COPIER > OPTION > DSPLY-SW
COPIER > OPTION > DSPLY-SW
UI-MOBP
Display/hide of mobile print
Lv.2 Details
To set whether to display or hide “Mobile Print” in the main menu.
Use case
Upon user’s request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: Hide, 1: Display
Default value
1
FCOT-DSP
ON/OFF of FCOT priority mode in usermode
Lv.1 Details
To set whether to display “Color/Black Priority for First Print Time” in
user mode.
When 1 is set, the home position of the Primary Transfer Rollers for Y,
M, C can be switched.
Use case
When setting “Color/Black Priority for First Print Time” in the user
mode
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
1
UI-COPYX
[Not used]
UI-SENDX
[Not used]
UI-BOXX
[Not used]
UI-INTRX
[Not used]
UI-CUSTM
ON/OFF of custom menu screen display
Lv.2 Details
To set ON/OFF of the custom menu screen display on the Control
Panel.
Use case
When not displaying the custom menu screen on the Control Panel
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
1
CNTCNFSW
ON/OFF of Counter Check screen display
Lv.1 Details
To set whether to display the Counter Check screen.
When 1 is set, the Counter Check screen can be displayed. The
setting value automatically returns to 0 (OFF) when the screen is
closed.
Use case
When checking the counter at servicing
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
0
COPIER > OPTION > DSPLY-SW
SCT-BTN
Set No. of shortcut buttons upper limit
Lv.1 Details
To set an upper limit on the number of shortcut buttons that appear
at the top of the Control Panel screen.
The settings for shortcut buttons are made in “Setting of Buttons at
the Top of the Screen” which is displayed by pressing the advanced
menu button on the Main Menu screen.
Use case
Upon user’s request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
When 1 is set, the number of shortcut buttons increases from 2 to 4.
However, the buttons become smaller in width, and the number of
characters that can be displayed decreases.
The character strings displayed are specified by the MEAP
application allocated to the shortcut button, and may not be fully
displayed in some cases. In this case, a measure such as decreasing
the number of characters on the MEAP application side needs to be
taken.
Display/adj/set range
0 to 1
0: 2 buttons, 1: 4 buttons
Default value
0
USER-DSP
Display/hide of login user name
Lv.1 Details
To set whether to display the name of the user who logs in to the
machine on the screen of the Control Panel (upper left area).
Use case
Upon user’s request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 2
0: Hide, 1: Display(User define), 2:Display(User name)
Default value
0
SDTM-DSP
Display/hide of auto shutdown shift time
Lv.1 Details
To set whether to display or hide auto shutdown shift time menu in
user mode.
Use case
Set 0 in Europe, and set 1 in areas other than Europe.
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 1
0: Hide, 1: Display
Default value
Europe: 0, Others:
1
SDWK-DSP
Display/hide of auto shutdown time set
Lv.1 Details
To set whether to display or hide auto shutdown time setting menu in
user mode.
Set 0 in Japan, and set 1 in areas other than Japan.
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 1
0: Hide, 1: Display
Default value
JAPAN: 0, Other:1