8
8
8-226
8-226
Service Mode > COPIER > OPTION > ACC
Service Mode > COPIER > OPTION > ACC
COPIER > OPTION > ACC
CC-SPSW
Support setting of control card I/F
Lv.2 Details
To set support level for control card (CCIV/CCV) interface.
To keep processing performance of printer engine, select “1: Priority
on speed”.
To correctly stop the output by the upper limit number of sheets,
select “2: Priority on upper limit number of sheets”.
Use case
Upon user’s request (when connecting to the external counter
management system using the control card interface)
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
With priority on speed, output cannot be correctly stopped by the
upper limit number of sheets.
With priority on the upper limit number of sheets, processing
performance of the printer engine is decreased depending on pickup
location.
Display/adj/set range
0 to 2
0: No support, 1: Priority on speed, 2: Priority on upper limit number
of sheets
Default value
0
USB-MSK
[Not used]
UNIT-PRC
Setting of Coin Manager currency unit
Lv.2 Details
To set currency unit to be handled with Coin Manager
Use case
At installation of Coin Manager
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 6
0: Japanese yen, 1: Euro, 2: Pound, 3: Swiss Franc, 4: Dollar, 5: No
currency unit (no fractional unit), 6: No currency unit (with fractional
unit)
Default value
0
IN-TRAY
Presence/absence of Second Delivery Tray
Lv.1 Details
To set whether the Second Delivery Tray is installed or not.
When the Second Delivery Tray is installed, set 1.
Use case
When the Second Delivery Tray is installed
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: Not installed, 1: Installed
Default value
0
COPIER > OPTION > ACC
DA-PUCT
Set pickup/delivery comctn at DA charge
Lv.2 Details
When a pickup and delivery notification error occurs due to network
failure, etc., the print operation might be done without charging.
This is to set the number of sheets that can be picked up after the
machine receives Ack single from DA.
When the value is decreased, the number of prints to be made
without charging is decreased, but the productivity may decrease.
When the value is increased, the productivity does not decrease, but
the number of prints to be made without charging is increased.
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
As the value is smaller, the number of prints to be made without
charging is decreased, but the productivity might be lowered.
Display/adj/set range
2 to 10
Default value
6
MIN-PRC
Set of Coin Manager minimum price
Lv.1 Details
To set the minimum amount to be handled with Coin Manager.
Enter 10 when specifying 10 Japanese yen as the minimum amount
to be handled with the Coin Manager that supports Japanese yen.
In the case to specify 1 to 4 (Euro/Pound/Swiss Franc/Dollar) by
going through the following: COPIER> OPTION> ACC > UNIT-PRC,
entry is in fractional unit. Entry of 50 indicates 50 cents ($ 0.50).
Use case
At installation of Coin Manager
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
This mode is enabled when selecting 4 for the following: COPIER >
OPTION > ACC > COIN.
Display/adj/set range
0 to 9999
Default value
10
Related service mode
COPIER> OPTION> ACC> COIN, UNIT-PRC
MAX-PRC
Set of Coin Manager maximum price
Lv.1 Details
To set the maximum amount to be handled with Coin Manager.
Enter 8800 when specifying 8800 Japanese yen as the maximum
amount to be handled with the Coin Manager that supports Japanese
yen.
In the case to specify 1 to 4 (Euro/Pound/Swiss Franc/Dollar) by
going through the following: COPIER> OPTION> ACC > UNIT-PRC,
entry is in fractional unit. Entry of 50 indicates 50 cents ($ 0.50).
Use case
At installation of Coin Manager
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
This mode is enabled when selecting 4 for the following: COPIER >
OPTION > ACC > COIN.
Display/adj/set range
0 to 9999
Default value
8800
Related service mode
COPIER> OPTION> ACC> COIN, UNIT-PRC